The parameters that can be modified are listed in the following table.
Code
Name
L0
Heating priority
Period between 2
L1
filtration pump starts
L2
Timer setting
Power OFF remember
L3
function
Background light
L4
setting
L5
Unit operation mode
4.6 I Wiring diagrams
See the wiring diagrams at the end of this document.
Range
0 : Heating priority output active (P1P2 powered)
1: Heating priority activated
Filtration pump works 5 min per L1 min (L1 range :
3 - 180) to check if heating is needed
0 : timer function OFF
1 : timer function ON
0 : OFF
1 : ON
0 : No background light
1 : light ON constantly
2 : light ON if operating, light OFF if no operation
0 : Heating only
1 : Cooling only
2 : Heating & Cooling
3 Cooling / Heating / Auto / Quick Heating /
Ecosilence / Heating mode / Quick Cooling /
Ecosilence / Cooling mode
Default
1
120
1
EN
1
2
3
27