IOMM
AC Power Connection
WARNING
RISK OF FIRE
•
•
•
4.6.1 Remove the six screws on the top panel of the charger
(Figure 14) with a TORX TX30, and then remove the panel.
Figure 14 Six Panel Screws,
Top Panel View
Webasto Charging Systems, Inc.
Use VAC input (indicated above) only on circuits with a
branch circuit protection in accordance with the NEC NFPA
70 to reduce the risk of fire.
These circuits (maximum CB size) also are to be consistent
with the supply current (input amps) indicated in section 3
for the respective number (2–5) and voltage (48V or 80V) of
fitted modules and cabinet size (3 or 5 bays).
Ensure that the AC wiring (minimum AC input wire size
[AWG]), indicated in section 3, meet NEC requirements.
Refer section 3 also for AC input voltage specifications
ProCore Edge North America
VAC Input
3-Phase 480V AC
M6 Screws (2021-2022)
M5 Screws (2023 and later)
21 of 68
31241-03-0202