Use the appropriate minimum wire size (gauge) or larger for the
maximum kilowatt rating of the charger. See section 3 for the
minimum fitted AC input wire size (AWG) per NEC.
The AC service entrance provides two-hole sizes.
4.6.2.1. Use the provided round panel to use the smaller hole size,
or remove this panel to use the larger hole size.
4.6.2.2. Place an appropriate cable gland or conduit clamp in this
AC service entrance hole to secure the cable or conduit.
4.6.3. Connect the three-phase AC input power cables.
Ensure that ground and power cables have been properly stripped
(of approximately 0.5 in. [12.7 mm] of insulation from the ends).
Loosen the AC input terminal screws, with a flathead screwdriver,
and insert the stripped ends of the ground and power cables.
(Figure 16 and Figure 17)
4.6.4. Re-tighten the screws with a minimum to maximum torque
of 22.2 in-lbs (2.5 Nm) to 26.4 in-lbs (3 Nm), respectively. AC line
input positions are interchangeable because the three-phase input
is not phase specific.
4.6.5. Ensure that the cable gland or conduit clamp has been
properly tightened.
31241-03-0202
Webasto Charging Systems, Inc.
24 of 68