Descargar Imprimir esta página

GRE EESB55 Manual Del Usuario página 8

Electrólisis de sal
Ocultar thumbs Ver también para EESB55:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 9
• Setting too low potentiometer
• Unit inversion fau t
• pH too high
These anomalies are indicated by the blinking red led.
- Cleaning the pool drainage filter:
Stop the chlorinator during any handling of the filter's valve: cleaning, rinsing, emptying...
9. Instructions for use of the electrode
The electrode is a wear part which depends on the following factors longevity:
- Rate of salt :
Never operate the electrolyzer with a salt content of less than 3.2 g / l.
- Water temperature and wintering :
Cut operation as soon as the water temperature drops to 15 º C.
If continuous filtration during the cold period, remove the electrode from the vase and repla-
ce the plug supplied for this purpose.
- Settings
Adjust chlorine production using the potentiometer and according to the desired rate.
- Reverse polarity :
Polarity reversal is carried out every 4 hours. To manually reverse the polarity of the potentio-
meter set the cursor to 0. Wait 2 minutes before repositioning the button to the desired level of
production.
10. The chemical reaction of the electrolyzer
The electrode under the action of the electric current dissociates molecule of salt (NaCl) chlo-
rine ions (NaOCl) and sodium.
The chlorine ions (sodium hypochlorite - NaOCl), in contact with water (H2O), is divided into
chlorine (hypochlorous acid - HOCl) and sodium hydroxide (NaOH). It is the active chlorine
(the hypochlorous acid - HOCl), which is the active ingredient and disinfectant.
11. Warranty
The electrolysis unit is warranted by the manufacturer against manufacturing faults for a
minimum period of 2 years counting from the delivery date.
Electrode: minimum 2 year warranty. This warranty does not cover breakdowns caused by
negligence, improper use, improper installation, modification, disassembly, corrosion, failu-
re to undertake maintenance or wintering, misuse, flooding, lightning strike or damage fo-
llowing a fall or blow.
Return all equipment for overhaul or repair is postage paid by the user.
The manufacturer reserves the right to change, without prior notice, shape, design or appea-
rance of products.