Initialisation
Before putting the table into operation:
Crew all components tightly together.
Attach the power supply (7) to the table.
Fix all cables using cable holders (J) and (L).
Keep in mind that your desk is height adjustable. The power supply cable must be able to follow the
movement of the desk completely.
Now please perform the initial  Reset.
Carry out a "Reset" at regular intervals - at least 1 x per month.
Click-Codes
As soon as the switch is connected, the control box uses installed relays to inform the user about system
status and the reason for the last shutdown:
Code
Normal operation: The system is working normally.
2x
Emergency operation:
1x
The system is in emergency operation mode. The Actuators cannot be used. Check the error code.
Last shut-off incomplete / forced reset:
Check the error code. If the control box could not complete a data-saving process before power
3– 6x
was lost, it will click 4–5 times during its next start-up and go into reset mode.
Error code 81 will not be shown in this case.
(VXBHM2C)
English
Message
RESET-MODE
When putting your table into service fort he fi rst time, please perform a reset:
Press the paddle down until the table
has moved to the lowest position
Reset
Release the paddle
Press the paddle down again for at least
6 seconds. Don't release earlier.
Your frame can now be used normally. By pressing the paddle up or down the table moves as you wish and
stops, as soon as you release the paddle.
Troubleshooting
Problem
Possible cause
Cables or connectors defective.
Table is slanted.
Height adjustment
Lifting columns not syncronized.
does not work
Fault in the conrol unit.
Max. continuous use time exceeded
(duty cycle).
There was a power failure while the
table was in motion.
The table only
moves downwards.
The power supply was disconnected
while the unit was moving.
If your problem couldn´t be solved or is not listed here, please contact your customer service for further
advise.
English
Table moves down
Lifting columns move down a bit further to
their mechanical limit to synchronize
Solution
Check all cables and connections.
Check your wall outlet.
Bring your table into a level position.
Perform a  Reset.
Let the unit cool down for
20 Minutes.
Perform a position reset by
performing a  reset.
(VXBHM2C)

Publicidad

loading

Este manual también es adecuado para: