Changing the Displayed Unit of Measurement (CM / Inch)
The height of the tabletop can be displayed in centimetres as well as in inches.
To change the displayed unit of measurement:
1. Press and hold the following Keys for 3 seconds:
1
2
Memory Position Keys 1 and 2 and
UP Key
▸ The display shows "S" and a number, e.g. "S 7".
2. Press the button UP Key until the display shows "S 5".
▸ The display shows "S 5".
3. Press the SAVE Key.
▸ If the display was previously set to cm,
SAVE
it is now set to inches.
▸ If the display was previously set to inches,
it is now set to cm.
Factory Reset
Attention: The positions saved so far will be lost.
1. Press and hold the following Keys for 3 seconds:
1
2
Memory Position Keys 1 and 2 and
UP Key
▸ The display shows S and a number (e.g. "S 4")
2. Press the DOWN Key until the display shows: "S 0".
▸ The display shows: "S 0".
SAVE
3. Press the SAVE Key.
The switch has now been reset to its factory settings. It is now in the same state as it was during the fi rst
start-up.
(VXBHM2C)
English
Error messages on the display
Signal
H OT
E 00
Code
E00
Internal Error Channel 1
E01
Internal Error Channel 2
E12
Defect Channel 1
E13
Defect Channel 2
E24
Overcurrent Motor M1
E25
Overcurrent Motor M2
E48
Overcurrent Motor Group
E36
Plug detected in M1
E37
Plug detected in M2
E55
Sync Error, Motor Group
Stop due to power output
E62
control
Collision detected (ISP
E60
Activated)
E61
Motor Replaced
E65
Overcurrent while driving
E67
High Voltage Detected
E71
Collision Sensor Defective
E81
Internal Error
Do not use the table system if the problems persist.
Contact your dealer for more information.
Message
Overheating protection has been
activated. Duty cycle possibly
Wait for the overheated components to cool.
exceed.
Read the table below to fi nd the correct
An internal error has occurred.
response to the error code shown.
Message
Required Actions
Disconnect the Control Box from the Mains.
Contact your dealer for more information.
Disconnect the Control Box from the Mains. Fix the external short
circuit. Ensure all cables are connected correctly.
Reconnect the system, then operate as normal.
Check that nothing is blocking the table's range of movement.
Remove excess load from the table.
Contact your dealer for more information.
Plug in the correct motor. Ensure all cables are connected correctly.
Perform a Factory Reset. Perform a Position Reset Procedure.
Remove excess load from the table. Perform a Factory Reset.
Contact your dealer for more information.
Check that nothing is blocking the table's range of movement.
Remove excess load from the table.
Contact your dealer for more information.
Release all Keys and wait for the Drive Back function to be completed,
then operate as normal.
Plug in the correct motor. Ensure all cables are connected correctly.
Perform a Factory Reset. Perform a Position Reset Procedure.
Check that nothing is blocking the table's range of movement.
Remove excess load from the table.
Contact your dealer for more information.
Disconnect the Control Box from the Mains.
Contact your dealer for more information.
Perform a Factory Reset. If the error persists
contact your dealer for more information.
Disconnect the Control Box from the Mains. Restart and perform a
Factory Reset.
English
Required Actions
(VXBHM2C)

Publicidad

loading

Este manual también es adecuado para: