d. Before re-introducing the filters, it is good practice to shake then to eliminate the
water accumulating during washing.
If the filters (7) are damaged, replace them.
e. Make sure that the filters (7) are completely dry.
f. Re-position the filters (7) correctly in the relative seats.
g. Suck possible fluff from the grille.
Do not use the appliance without the filter (7).
8.2 - MAINTENANCE
If you do not intend to use the appliance for a long period of time, work as follows:
a. Activate the fan only mode for a few hours to dry the interior of the appliance.
b. Stop the air appliance and disconnect the power supply.
c. Clean the air filter.
d. Close the water valves.
e. If the risk of frost exists, make sure that antifreeze liquid has been added to the
system, empty the system otherwise.
The antifreeze function is not active.
Checks before resuming use of the air conditioner:
a. Clean the filters after a long period of inactivity of the air conditioner.
b. Check that the air outlet or inlet are not obstructed (especially after a long period
of inactivity of the air conditioner).
9 -
TROUBLESHOOTING
If one of the following anomalies occurs, switch the appliance off, disconnect
it from the electric power supply and contact your dealer.
a. A safety device, such as a fuse or switch, intervenes frequently.
b. The appliance has a water leak.
c. Other malfunctioning.
9.1 - LOCKED FAN FUNCTION
a. When the printed circuit board receives from the fan motor an incorrect speed
feedback (motor not connected, locked, broken, etc.), the green led starts blinking
6 times after 5 seconds and the speed signal to the motor is set to minimum speed.