Descargar Imprimir esta página

Husqvarna PG 510 Manual Del Usuario página 12

Ocultar thumbs Ver también para PG 510:

Publicidad

Idiomas disponibles

Idiomas disponibles

8. Attach new diamond tools to the tool plate with a soft
hit of the hammer.
9. Attach the tool plate straight (A) on the grinding disc.
B
A
10. Push the center tabs together and rotate clockwise
(B) to lock the tool plate to the grinding disc (C).
11. When the diamond tools are replaced, put the
product into operation position.
To do before you operate the product
1. Read the operator's manual carefully and make sure
that you understand the instructions.
12
C
2. Do daily maintenance. Refer to
on page 14 .
3. Make sure that the product is assembled correctly
and is not damaged.
4. Put the product on the work area.
5. Make sure that there are diamond tools on the tool
plate and that they are tightly attached.
6. Connect the dust extractor to the product. Refer to
To connect a dust extractor on page 14
7. Adjust the handlebar to set the necessary work
height.
8. Make sure that the motor cable is connected to the
electrical enclosure before the product is connected
to an electric socket.
9. Connect the power plug of the product into the mains
outlet.
10. Turn the emergency stop button clockwise to make
sure that the emergency stop is disengaged.
11. Make sure that you know in which direction the
motor rotates.
To change in which direction the motor rotates
CAUTION:
to rotate in only one direction.
Daily maintenance
The T-Rex tools are made
1146 - 003 - 21.03.2024

Publicidad

loading