Descargar Imprimir esta página

Kärcher NT 75/1 Me Ec H Z22 Manual Del Usuario página 14

Ocultar thumbs Ver también para NT 75/1 Me Ec H Z22:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
Filter cover handle
35
Type plate
36
Symbols on the device
Dust class
WARNING: This machine contains dust that is harmful
to your health. Emptying and maintenance, including
removal of the dust bag, may only be performed by
technical specialists wearing suitable personal protec-
tive equipment. Do not operate the device without the
complete filtration system.
Zone 22, safety filter bag
Do not vacuum any sources of ignition!
Suitable for vacuuming inflammable
dusts of dust explosion classes in zone
22.
Safety filter bag
Order number
Safety instructions
DANGER
Risk of injury, explosion and damage
Observe the following safety instructions when handling
the device.
● The electrical connection (mains plug) must be
made outside the hazardous area (Zone 22).
● The included accessories are electrically conduc-
tive. Only the accessories listed in the appendix
(standard accessories / special accessories) may
be used!
● Do not vacuum without filter elements in place, oth-
erwise the suction motor will be damaged and there
will be a health risk due to increased fine dust emis-
sions!
● Observe the safety regulations for the materials be-
ing vacuumed. During proper/improper operation,
parts (e.g. air outlet) of the vacuum cleaner can
reach up to 105 °C.
● The minimum ignition temperature (MIT) of the dust
cloud is ≥160 °C and the MIT of dust with a dust
thickness of 5 mm is ≥180 °C.
● The use of an extension cord is prohibited.
Behavior in the event of an emergency
DANGER
Risk of injury and damage in the event of a short-cir-
cuit or other electrical faults
Danger of electric shock, danger of burns
Switch off the device and unplug the mains plug.
14
1. Unpack the device and install the accessories.
Danger from dust that is harmful to your health
Respiratory sicknesses through inhalation of dust.
Do not vacuum without correctly installed filter ele-
ments, otherwise a danger to health from increased fine
dust emission is present.
Note
The device is not suitable for the vacuuming of dusts
with extremely low minimum ignition energy (ME <
1 mJ),e.g. toner, mesh, aluminium powder, lead acid
suitable.
1. Bring the device into the working position and se-
2. Plug the suction hose into the suction hose port.
3. Check the filling level in the dirt receptacle before
4. Attach the desired accessory.
The device is equipped with a suction power monitor. If
the air speed in the suction hose drops below a speed
of 20 m/s, the "vacuum pressure" indicator light flashes
red (see Help with malfunctions).
Note
The indicator light can light up intermittently during nor-
mal operation (e.g.when working with a floor nozzle)
6.904-420.0
when the air quantity is reduced (cross-section reduc-
tion) and the vacuum pressure increases as a result.
Note
In these cases, however, it is not a defect, but an indica-
tion that the air quantity has reduced and the vacuum
pressure has increased, as indicated above.
Static charges are discharged through the earthed con-
nection nozzles. This prevents sparking and electric
shocks with electrically conducting accessories (includ-
ed in the scope of delivery).
● The unit is equipped with a safety filter bag with
Note
All types of dust up to dust class H can be vacuumed
with this device. The use of a dust collection bag (for or-
der no. see filter systems) is required by law.
Note
The device is an industrial vacuum cleaner for vacuum-
ing dry, conducting, combustible dusts with workplace
limit values (AGW).
● Unused flat fold filters may only be stored and trans-
● The slats of the flat fold filter many not be touched
Danger from dust that is harmful to your health
Respiratory sicknesses through inhalation of dust.
Do not vacuum without a flat fold filter and safety filter
bag, otherwise a danger to health from increased fine
dust emission is present.
English
Preparation
Illustration B
Starting up
WARNING
cure it with the parking brake if necessary.
starting work and empty the receptacle if necessary.
Automatic suction power monitor
Anti-static system
Dry vacuuming
sealing cap, order number 6.904-420.0 (5 pieces).
ported in their packaging (cardboard box).
during installation.
Illustration C
WARNING

Publicidad