Package contents

1 cordless angle grinder
1 additional handle
1 blade guard (pre-assembled)
1 two-hole mounting spanner
1 cutting disc (pre-assembled)
1 set of operating instructions

Technical details

Cordless angle grinder: PWSA 20-Li B3
Rated voltage:
Rated idle speed:
Disc width:
Thread size:
Battery: PAP 20 A3*
Type:
Rated voltage:
Capacity:
Cells:
High-speed battery charger: PLG 20 A3*
INPUT:
Rated voltage:
Rated power
consumption:
Fuse (internal):
OUTPUT:
Rated voltage:
Rated current:
Charging time:
Protection class:
* BATTERY AND CHARGER ARE NOT INCLUDED
PWSA 20-Li B3
(DC)
20 V
n 2500–10000 rpm
Ø 125 mm
M14
LITHIUM ION
(DC)
20 V
4 Ah
10
230–240 V ~ , 50 Hz
(AC)
120 W
T3.15A
3.15 A
(DC)
21.5 V
4.5 A
approx. 60 min
II / (double insulation)
Noise and vibration data:
Noise measurement value determined in accord-
ance with EN 60745. The A-rated noise level of
the power tool is typically:
Noise emission value:
Sound pressure level:
Uncertainty:
Sound power level:
Uncertainty:
Wear ear muffs!
Total vibration value:
Surface grinding main handle: a
Uncertainty:
Surface grinding
Additional handle:
Uncertainty:
NOTE
The vibration level specified in these instruc-
tions has been measured in accordance with
a standardised measuring procedure and
can be used for equipment comparisons. The
specified vibration emission value can also be
used to make an initial exposure estimate.
WARNING!
The vibration level varies depending on the
use of the power tool and may be higher
than the value specified in these instructions
in some cases. Regular use of the power tool
in this way may cause the user to underesti-
mate the vibration. Try to keep the vibration
loads as low as possible. Measures to reduce
the vibration load are, e.g. wearing gloves
and limiting the working time. Wherein all
states of operation must be included (e.g.
times when the power tool is switched off and
times where the power tool is switched on but
running without load).
L
= 83 dB(A)
PA
K =
3 dB
L
= 94 dB(A)
WA
K =
3 dB
= 2.698m/s
h, AG
K = 1.5 m/s
2
a
= 3.284 m/s
2
h, AG
K = 1.5 m/s
2
GB │ MT
 57
2

Hide quick links: