If a minor problem occurs, it usually can be solved quite easily when the cause is found by using the check list below.
What's the problem?
Cleaner
won't turn on.
[What's
the cause?
What's the solution?
]
Not firmly plugged in.
Plug unit in firmly.
No voltage in wall plug.
Replace fuse or reset circuit.
What's the problem?
Agitator brush roll brushes aren't turning.
[What's
the cause?
What's the solution?
j
Hard Surface mode selected on Surface Selector
Select a suitable carpet mode setting.
control dial.
Agitator
brush roll is obstructed.
Disconnectcleaner from electrical outlet. Turn c]eaner over and
remove any debris that has accumulated on the agitator brush
roll.
[What's
the cause?
Filter bag full.
Incorrect
carpet height setting.
Blockage in system.
What's the solution?
Change filter bag.
Select another carpet height setting on the Surface Selector
control dial,
Clear blocl<age(see"Clearing blockages" section),
[What's
the cause?
What's the solution?
]
Incorrect
carpet height setting.
Select a hi_her carpet height setting on the Surface Selector
control di_[.
What's the problem?
Cleaning
tools won't pick up.
[What's
the cause?
What's the solution?
j
Filter bag full.
Change filter bag.
Blockage in system.
Clear blockage (see "Clearing blockages"
section).
What's the problem?
Powered pet hair cleaning tool agitator brush roll won't turn.
[What's
the cause?
What's the solution?
]
Too much pressure being applied to tool.
Blockage in turbine channel.
Broken or worn belt.
Low cleaner suction.
Continue using tool applying light pressure.
Remove blockage.
Rep]ace be]t.
Refer to items under "Cleaner won't pick up".
19