2. CAUTIONS FOR CHARGING
WARNING
Power mode.
- Strictly follow the sequence of steps.
- Please use 5V2A adapter - not included in the set.
Fig.3.1
Product:
1. Hub
2. duckbill valve
3. milk collect cup + seal ring
4. flange 24mm
5. Silicone Diaphragm Chamber
4. KEY / MODE OPERATION INSTRUCTIONS
Fig. 4.1 Display
Vibration Mode
Expression Mode
Depth Mode
Key Operation :
Power on and off: short press the power button to turn on, long press the power
button for 1.5S to shut down. Start / pause: short press the power button to pause, short
press the power button to start.
Suction Gear Increase. In working mode, short press „+" to increase the suction,
each press increases the suction by one gear, suction gear P1~P8.
Suction Gear Decrease. In working mode, short press „-" to decrease the suction,
each press decreases the suction by one gear, suction gear P8-P1.
Mode key : short press the mode key to switch modes in working state, and
switch in a circular manner.
Cleaning and disinfection are two different things that must be done separately to care for mother and baby while maintaining the characteristics of the breast pump.
Cleaning - Cleaning of component surfaces by physically removing contaminants.
Disinfection - kills live organisms such as bacteria or viruses that may exist on the surface of the part.
20_100_instrukcja_ms001.indd 4-5
20_100_instrukcja_ms001.indd 4-5
- Make sure that the power adapter matches the voltage of the local power supply.
- Plug the power adapter USB Type - C cable into the hub. Fig.2.1
- Plug the power adapter into a power outlet. At the moment the hub shouldn't be
used. Fig.2.2
3. PRODUCT ACCESSORIES
Silicone Diaphragm Chamber fig. 3.2:
1. Front cover of chamber
2. Back cover of chamber
3. Silicone diaphragm seal
Silicone breast funnels 3 different sizes 17, 19, & 21mm – fig. 3.3
Stopper for closing milk collect cup. fig.3.4
USB - type C cable – fig. 3.5
Low Battery Alert / Auto Shutdown
When the battery is low, the indicator light flashes and automatically powers off after
10 seconds.
Charging Status
The battery indicator flashes when the adapter is connected for charging.
(Fully charged status)
Screen Display Instructions
In working condition, press any key to wake up the screen, the bright screen display time
is about 20 seconds.
(Time display status)
Press the suction gear increase or decrease key to switch the corresponding suction
gears.
Press the mode key to switch the mode.
Press the pause key to pause the working mode, the breast pumping time is constantly
displayed on the screen.
5. CLEANING
4
When to clean
disassemble
Split before first use
cleaning
disinfect
Wash after each use
disassemble
cleaning
Once a day
disassemble
disinfect
Check all components for damage and replace damaged or worn components.
Caution ! Care should be taken when cleaning breast pump accessories to avoid
damaging them.
As shown on fig.5.1, remove the flange and milk container, and push down the air
chamber with your thumb to separate the air chamber from the hub .
As shown on fig.5.2, use your thumb to block the air inlet of the air chamber to make it
form a sealed chamber , and the other thumb to press the silicone diaphragm seal , thus
opening the front and bac covers of air chamber for cleaning .
Cleaning in the sink before first use and after each use.
1. Rinse all parts with clean drinking water (approx .20°C (68°F)).
6. ASSEMBLING
Assemble the Breast Pump Components fig.6
Disassemble and clean the parts that come in contact with breasts and breast milk
immediately after use to avoid breastmilk residue causing bacteria.
1. Hold the silicone diaphragm seal with the convex side upward and place it on the
front cover of the air chamber. Align the front cover of the air chamber and the silicone
diaphragm seal with the back cover of the air chamber to assemble a tight chamber.
2. Make sure, that all the edges of the elements are closely matched to each other.
3. Push the assembled air chamber with the hole side up into the hub, when you hear a
click sound, the assembly is complete.
4. Milk container assembly: align milk container front shell with the back shell, press the
assembled container around to ensure that the container is completely sealed. There is a
special silicone gasket to match elements tight.
5. Place the duckbill valve on the milk outlet hole of the milk container, press down
gently to assemble the duckbill valve.
6. Push the assembled milk container into the assembled hub in Figure 3, when you hear
the click sound, the milk container assembly is completed.
disassemble
disassemble
cleaning
cleaning
disinfect
disinfect
disassemble
disassemble
cleaning
cleaning
disassemble
disassemble
disinfect
disinfect
2. Wash all parts in plenty of warm soapy water (approx. 30°C (86° F )). Use a detergent
that you can purchase, preferably one that is free of artificial fragrances and colours (pH
neutral) is recommended.
3. Rinse the parts with clean drinking water (approx. 20°C (68° F )) for 10-15 seconds . Dry
after washing.
Disinfection - before first use and once a day.
Fully immerse the milk collect cup, silicone duckbill valve, silicone flange in water, boiling
for no more than 5 minutes, dry after disinfection.
Dry - wipe to dry with a clean cloth, or place on a clean cloth to dry, place washed parts in
a clean storage bag or in a clean environment, do not put wet parts in airtight containers
/ storage bags. Be sure to dry any residual moisture.
To clean the main unit, the shell can be wiped with a clean, moist (non - dripping) cloth.
7. Align the end of the silicone flange with the charging port mark to the charging port
of the hub and assemble it to the hub.
8. Both thumbs in downwards, press the center of the silicone flange and push it
completely into the hub.
Installation Notes.
CAUTION
- Before touching the breast and breast pump parts, wash your hands thoroughly with
water and soap (at least one minute) and dry them with a clean towel or disposable
paper towel.
- In addition, milk containers and components may be damaged if they are not properly
handled, such as dropped, over - tightened, or knocked over.
- Care should be taken when holding and placing milk containers and components.
- Please only use electric original parts, otherwise there will be air circuit failure that
cannot be used.
- Before use, all accessories must be ensured to be completely dry.
- Please perform all steps carefully and assemble the lactation converter accessories
correctly, otherwise you may not get a good negative pressure.
5
08.01.2024 16:04:17
08.01.2024 16:04:17