▷ Position the plate in the dovetail guide and
lower it into the plaster mush until the plate
rests flat on the putty.
Fig. 20
▷ After 20-35 minutes: loosen the vestibular
putty sleeve.
Fig. 21
▷ Lift off the impression from the carrier.
Fig. 22
A P P L I C A T I O N
5.5
Removing from the Form
NOTE:
Irreparable dimensional deviations due to plas-
ter expansion.
▷ Remove the dental arch from the plinth plate
latest after 35 minutes.
▷ Do not lever off against the plinth plate due
to the risk of breaking the dental arch.
▷ Place the blade tip of the plaster knife between
the impression material and the plaster.
Fig. 23
▷ Remove the model from the impression by turn-
ing the knife blade.
The back of the blade rests on the tray rim and
the tip of the blade lifts the model out of the
impression.
Fig. 24
▷ Place the model with the split noses facing
downwards flat onto your hand.