Descargar Imprimir esta página

CEMO DT-Mobil PRO Hybrid 980 l Basic Manual Del Usuario página 54

Sistema de depósito móvil para diésel

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

GB
7. Maintenance and inspection
7.1
Safety measures
i
Important!
The operator must provide any protective clothing that may be required.
Who can carry out maintenance and inspection work?
» Normal maintenance work can be carried out by trained operating personnel.
i
Important!
Inspections of the filling station may only be carried out by an authorised, registered inspection
agency with respect to the ADR approval.
7.2
Maintenance and inspection table
Interval
Assembly
As
Outside of
required
filling station
Container
Monthly
Line/hose
system
Moving parts
of the tank
Annually
Leakage
probe
Every two
and a half
Filling station
years
Every five
Filling station
years
7.3
Troubleshooting
Fault
The delivery nozzle does not
switch off automatically or
switches off too late
Pump is running, but no
output
Pump is running, but little
output
Liquid in the nozzle pocket
Tank can only be filled to
about halfway when refilling
with automatic nozzle.
When refilling with a fixed
connection, the tank is not
ventilated quickly enough
54
Action
Remove any adhering dirt and diesel fuel.
Repair damage to the zinc coating by cold galvanising or repair damage
to the paint with 2-component PU paint RAL 7036 "platinum grey".
Visual check for damage
Check hoses for cracks and porosity, check valves for leaks (replace
defective parts).
Lubricate hinges and lock with a few drops of universal oil.
Visual and functional check as described in the LS-03 leakage probe
operating instructions.
Inspection according to ADR 6.5.4.4.1 b) and 6.5.4.4.2
Documentation in the test report (see section 10)
If the test is successful - imprint on name plate (month/year)
Inspection according to ADR 6.5.4.4.1 a) and 6.5.4.4.2
Documentation in the test report (see section 10)
If the test is successful - imprint on name plate (month/year)
Possible cause
The delivery spout is not
correctly inserted into the
tank nozzle
Ball valve on delivery line
closed
Hoses are blocked or kinked
Air bubbles in the liquid
Filter clogged
Escaped liquid
Incorrect filling connection
used
Filling volume flow too high
Insuffcient ventilation
Solution
Fully insert the delivery spout into the
tank nozzle
Open ball valve
Check hoses
Leave the tank to stand for a few
minutes
Clean filter (see section 7.4)
Clean the nozzle pocket (see section
7.5)
Use filling nozzle under the 2" screw
cap (brass).
Reduce filling volume flow
Unscrew aeration and ventilation plug

Publicidad

loading