14. Additional tank for urea solution
AUS 32 (PRO Hybrid COMBI)
14.1
Layout
8
8
Filling opening with valve
Y
Y
Delivery nozzle
Z
Z
Switch
8
8
14.2
Technical data
14.2.1
Additional tank for AUS 32
Dimensions L x W x H mm: 1068 x 712 x 505
Nominal volume:
14.2.2 12 V pump
Voltage:
Fuse:
Power:
Delivery rate:
max. delivery pressure:
Liquid temperature:
14.3
Electrical connection of the pump
see operating instructions for the pump, section 5
14.4
Initial setup
Unscrew the cap on filling opening
interior of the container for contamination and
clean it if necessary, e.g. with a vacuum cleaner.
Refill the container using a delivery nozzle with
an automatic shut-off. After refilling, screw the cap
back on the filling opening.
Make sure that the pump is switched off. Connect
the terminal clamps to a suitable voltage source
and switch on the pump at the switch.
58
Y
Y
Z
Z
200 L
12 VDC
25 A (at the pole terminal)
220 W
approx. 25 l/min
1.1 bar
-5°C to +40°C
. Check the
Y
Y
Please note:
Despite increased caution, contaminants may
have entered the system during assembly
of the individual parts. Due to the high purity
requirements during setup, we therefore
recommend that the first 5 litres, approximately,
are not used to fill the vehicle, but are collected
separately.
The filling station is now ready for operation.
14.5
Use
14.5.1
Filling of vehicles/containers
Take delivery nozzle
Z
Z
insert the delivery spout into the container/tank to
be filled.
Connect the power supply and switch on the pump
at switch
.
8
8
To dispense urea solution, now pull the actuating
lever of the delivery nozzle and, if necessary, slot
the small flap below the lever into the toothing at
the desired level. The delivery nozzle switches
off automatically when the container/tank of the
vehicle to be refuelled is full. If you wish to stop
dispensing before the tank is full, pull the lever
briefly to disengage and release it.
After the delivery spout has drained, remove the
nozzle from the filler neck and roll up the hose.
Place the delivery nozzle back in the holder. Shut
off the pump.
Never let the pump run dry for a prolonged period
of time if the container is empty. It can only be
safely run dry on a limited basis and can be
damaged by overheating.
Do not kink the delivery hose when refuelling and
winding it onto the container.
i
Important:
The refuelling process must be
supervised at all times.
i
Please note:
Container ventilation and pressure relief
are performed automatically by integrated
valve
.
Y
Y
out of the holder and fully