13. Technical data
Height gauge
fi
Specification
Measuring range
fr
Measuring range extension
Graduations
it
Error limit
Repeatability – plane (± 2 σ)
hr
Repeatability – bore (± 2 σ)
Rectangularity error
nl
Gauging force
Measurement rate
no
Maximum positioning speed
By hand
Motorised with thumbwheel
pl
Drive
Compressed air supply
pt
Vertical measuring system in column
Resolution of vertical measuring system
sv
Temperature sensor error limit
Storage temperature and transport
temperature
sk
Operating temperature
Working temperature
es
Relative humidity, non-condensing
Maximum operating time
hu
Dimensions L x W x H
Weight
ro
Rechargeable battery
Nominal capacity
lt
Interfaces
sl
Power supply
Mains voltage
cs
Index of protection
26
Size 350
0–350 mm
0.01 / 0.005 / 0.001 / 0.0005 / 0.0001 mm
(1.8 + L/600) L (µm, L in mm)
5 µm
Incremental measuring system
255 mm x 278 mm x 688 mm
22.2 kg
Millimess connection socket on measurement slide
12 V DC / 3.8 A / type FW7405M/12
Size 600
170 mm
0.5 µm
1 µm
1.0 ± 0.3 N
5 / 8 / 11 / 15 / 20 mm/s
1000 mm/s
80 mm/s
Motorised
Installed compressor
0.1 µm
± 0.25 °C
-10 °C to +60 °C
+10 °C to +40 °C
+20 °C
Max. 65 %
14 h
255 mm x 278 mm x 938 mm
25.6 kg
Li-ion battery, 7.2 V
11500 mAh
2 USB 3.1 ports
Mini USB port
110–230 V AC / 50–60 Hz
IP 40
0–600 mm
6 µm