E5
Washing motor
failure
E6
Water heating
tube failure
E7
Water heating
temperature
sensor
malfunction
E8
Converter model
matching error
E9
Inverter
communication
failure
E91
Communication
failure of the
drying module
E10
Inverter board
failure
E11
Auto-loading
pump failure
E12
Level sensor
failure
22
The motor wiring harness terminal is loose or the
wiring harness is faulty.
Motor temperature rise too high thermal protection
action (locked rotor failure, check the motor speed is
0 for 5 consecutive times, every 5 seconds interval)
The motor itself is faulty
Computer board failure
UVW short circuit; motor coil insulation is damaged
UVW wiring is off
Poor heat dissipation
The terminal of the heating pipeline is loose or the
wiring harness is faulty.
Heating tube failure
Computer board failure (or drying computer board
failure)
The terminal of the water heating temperature
sensor wiring harness is loose or the wiring harness
is faulty.
Temperature sensor failure
Computer board failure
Main board variant does not match converter model
The terminal is not plugged in or the wiring harness
is faulty.
Computer board or inverter board is faulty
The terminal is not plugged in or the wiring harness
is faulty.
The drying module or the main control board is
faulty.
The inverter board is interfered
Inverter board failure
The terminal is not plugged in or the wiring harness
is faulty.
Automatic delivery module failure
The terminal is not plugged in or the wiring harness
is faulty.
Automatic delivery module failure
Check whether the wiring harness
terminals are firmly connected or replace
the wiring harness
Check if the clothes are too much or stuck.
After power off and cooling for a period of
time, you can power on again.
Replace the motor
Replace computer board
Check if the wiring harness terminal is
shorted or replace the motor
Check whether the wiring harness terminal
is firmly connected or replace the wiring
harness
Waiting to cool down
Check whether the wiring harness
terminals are firmly connected or replace
the wiring harness
Replace the heating tube
Replace the computer board (or dry the
computer board)
Check whether the wiring harness
terminals are firmly connected or replace
the wiring harness
Replace temperature sensor
Replace the computer board
Reset the variant version
Replace the frequency converter
Check whether the wiring harness
terminals are firmly connected or replace
the wiring harness
Replace computer board or inverter board
Check whether the wiring harness
terminals are firmly connected or replace
the wiring harness
Replace the drying module or the main
control board.
Wait for the interference to disappear, then
power off and on again
Replace the inverter board
Replace the inverter board
Check whether the wiring harness
terminals are firmly connected or replace
the wiring harness
Check whether the wiring harness
terminals are firmly connected or replace
the wiring harness
Replace the automatic delivery module