OPERATION
PARALLEL OPERATION
See Figure 18.
Parallel operation gives you the ability to link two compatible
Westinghouse inverter generators for combined running and
peak power output.
DANGER
Never connect or disconnect the parallel cable leads
when a generator is running. Failure to follow this rule
may lead to serious personal injury or death.
WARNING
and right cables is very important, especially when the
generators are used with a transfer switch to supply
power to a building. To avoid serious personal injury
or damage to electrical devices, including the genera-
tors, do not try to power an electrical system in a build-
ing without using an approved transfer switch.
NOTICE
Connecting to a generator that is
not compatible can cause a low voltage output that
may damage tools and appliances powered by the
generator.
Use only the Westinghouse parallel cable that came with
your generator. Third party cables may not have the ability
to carry the increased voltage. If damage or loss occurs
to your cables, call Westinghouse customer service for
replacement.
The parallel cables and parallel ports are color-coded. There
is a third wire that carries the ground. Use the following
steps to connect the two generators.
NOTE: Be sure both generators have been shut down and
there are no devices connected to the outlet receptacles.
MAINTENANCE
WARNING
the spark plug boot (see figure 21) from the spark
plug when performing maintenance on the generator.
WARNING
with recommended or equivalent replacement parts.
Using an incorrect or incompatible part might create a
hazard that could result in serious personal injury.
WARNING
30 minutes before performing any maintenance pro-
cedure.
Fire and electrocution hazard.
Correct connection of the left
Accidental start-up. Disconnect
Replace damaged or worn items
Allow hot components to cool for
To install the parallel cable:
l Insert the cable ends of the same color into the matching
color parallel ports on the unit.
l Loosen and remove the ground terminal nut.
l Connect the ground wire to the terminal and reinstall the
ground terminal nut. Tighten securely.
Start one generator at a time. Wait for the first unit to run
at a stable idle before starting the second unit. Connect
one device at a time and allow the unit to stabilize before
connecting the next device.
To remove the parallel cable:
l Remove all devices from the generator's receptacles.
l Shut down both of the connected generators.
l Remove the parallel cable ends from the generator ports.
l Remove the ground terminal nut and ground wire. Be
sure to replace and tighten the ground terminal nut.
TRANSPORTING
l Turn off the generator.
l Allow the generator to cool a minimum of 30 minutes
before transporting.
l Replace all protective covers on the generator control
panel.
l Only use the generator's fixed handle to lift the unit or at-
tach any load restraints such as ropes or tie-down straps.
DO NOT attempt to lift or secure the generator by holding
onto any of its other components.
l Keep the unit level during transport to minimize the pos-
sibility of fuel leakage or, if possible, drain the fuel or run
the engine until the fuel tank is empty before transport.
CAUTION
generator or place it on its side. Fuel or oil can leak
and damage to the generator may occur.
WARNING
or gasoline. Wear protective clothing and equipment.
Wash all exposed skin with soap and water. Prolonged
skin contact with gasoline or engine oil may cause se-
vere skin irritation and other adverse reactions.
NOTICE
Check the physical condition of the
product prior to each use. Look for loose bolts, fluid
leaks, and other signs of wear. Replace all damaged
items. For replacement parts or assistance, contact
our customer service team.
To prolong the life of this product, follow the maintenance
instructions in this section. Contact customer service before