Backlight And Torch Light; Measuring Ac, Dc Or Ac+Dc Voltages - Metrix MTX204 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 85
It is recommended to follow this procedure when you use the meter for the first
time, or after long time without use:
Start the meter; make sure that all segments are displayed.
Check that on Continuity position, and without any input the meter display OL.
Take out both cords and short circuit, the beeper should sound.
Turn the rotary switch on V and check a known voltage (for example a battery)
and make sure voltage is correct.
When all the steps above are correct, you can start to use the meter.
3.3.

Backlight and Torch light

Then pressing the
(white) will light up.
Press again
On NCV position the backlight will blink red if AC live voltage is detected.
As default, the multimeter is set to automatic mode (AUTO). Whatever the quantity
being measured, pressing RANGE switches the instrument to manual mode to let you
select the desired range.
3.4.
Measuring AC, DC or
AC+DC voltages
The meter measures AC or DC
voltage. To minimize risk when
measuring an unknown voltage,
make sure to measure both AC
and DC voltage
1.
Turn the rotary switch to
(500 k).
key for more than 2s, both LCD backlight (blue) and torch light
for more than 2s to shut down the backlight.
(10 M),
31

Publicidad

Tabla de contenido
loading

Tabla de contenido