I. INSTALLATION INSTRUCTIONS
1. LOCATION
IMPORTANT
1. This icemaker is not intended for outdoor
use. Normal operating ambient temperature
s h o u l d b e w i t h i n 5 ° C t o 4 0 ° C . Wa t e r
connection is cold water only. Operation of
the icemaker, for extended periods, outside
of these normal temperature ranges may
affect production capacity.
2. The icemaker should not be located next to
ovens, grills or other high heat producing
equipment.
3. The location should provide a firm and level
foundation for the equipment.
4. Allow 15 cm clearance at rear, sides and
top for proper air circulation and ease of
maintenance and/or service should they be
required.
5. This appliance is not suitable for installation
in an area where a water jet could be used
and where dripping is not allowed.
6. Do not place anything on top of the icemaker
or in front of the louver.
7. This icemaker will not work at subfreezing
temperatures. To prevent damage to the
water supply line, drain the icemaker when
air temperature is below zero (see "II. 2.
PREPARING THE ICEMAKER FOR LONG
STORAGE").
8. The noise from this icemaker is 55 dB or
less.
9. Avoid prolonged exposure of the appliance
to direct sunlight.
10. T h i s a p p l i a n c e c o n t a i n s f l a m m a b l e
refrigerant in its cooling unit; maintenance
and recharging must therefore only be
carried out by authorized technicians.

2. ELECTRICAL CONNECTIONS

WARNING
THIS APPLIANCE MUST BE EARTHED
This icemaker requires an earth that meets the
national and local electrical code requirements.
To prevent possible severe electrical shock to
individuals or extensive damage to equipment,
install a proper earth wire to the icemaker.
Remove the plug from the mains socket
before any maintenance, repairs or cleaning is
undertaken.
* This appliance requires a separate 220 - 240VAC,
13A supply. The electrical supply must be protected
by a suitable circuit breaker.
* The main control box circuit breaker is rated at 6A
and should only be replaced by a qualified service
engineer.
* Usually an electrical permit and services of a
licensed electrician are required.
* If the supply cord and the plug should need to be
replaced, it should only be done by a qualified
service engineer.
For the U.K. and the Republic of Ireland only
* The wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wire in the mains lead of this
appliance may not correspond with the coloured
markings identifying the terminals in your plug,
proceed as follows:
The wire which is coloured Green-and-Yellow must
be connected to the terminal in the plug which is
marked with the letter E or by the symbol
coloured Green or Green-and-Yellow. The wire
which is coloured Blue must be connected to
the terminal which is marked with the letter N or
coloured Black. The wire which is coloured Brown
must be connected to the terminal which is marked
with the letter L or coloured Red.
* Should the socket outlets in the installation site not
be suitable for the plug supplied with your product,
the plug must be removed (cut off if it is moulded
on plug) and an appropriate plug fitted.
If the non-rewirable plug has been cut from the
power supply cord, it must be disposed of. There
should be no attempt to reuse it. Inserting such a
plug into a socket elsewhere presents a serious
risk of electrical shock.