1.2.c. ELECTRICAL AND PNEUMATIC CONNECTIONS
The electric hook-up used must be suit-
ably sized:
• for the electric power absorbed by the
machine, indicated on its data plate
(Fig. 1);
• the distance between the machine and
the power supply hook-up point, so that
voltage drops under full load do not ex-
ceed 4% (10% during start-up) compared
with the rated voltage specified on the
data plate.
- The operator must:
• fit a power plug on the power supply lead
in compliance with the relevant safety
standards;
• connect the machine to its own electrical
connection - A, Fig. 2 - and fit a differential
safety circuit-breaker with 30 mA residual
current;
• install protection fuses on the power line
that are suitably sized in accordance with
the indications provided on the machine
data plate (Fig. 1);
• connect the machine to an industrial
socket; the machine must not be con-
nected to domestic sockets.
An effective grounding connection is essential for correct operation of the machine.
Make sure that the available pressure and performance of the compressed air system
are compatible with what is necessary for correct machine operation - see the section
"Technical data". For correct machine operation, the compressed air supply line must
provide a pressure range from no less than 8.5 bar to no more than 16 bar and guarantee
an air flow rate greater than the average consumption of the machine, which is equal to
140 Nl/min (see technical data).