9. The high pressure system must not be started up and run
under pressure without all team members in position and
without the Operator having already directed his/her lance
toward the work area.
3.5
Safety during system maintenance
1. High pressure system maintenance must be carried out
in the time intervals set by the manufacturer who is
responsible for the whole group according to law.
2. Maintenance should always be performed by trained and
authorised personnel.
3. Assembly and disassembly of the pump and the various
components must only be carried out by authorised
personnel, using appropriate equipment in order
to prevent damage to components, in particular to
connections.
4. Always only use original spare parts to ensure total
reliability and safety.
5
TECHNICAL CHARACTERISTICS
Model
MW 32
MW 36
MW 40
MW 45
MW 50
MW 55
Flow rate
Rpm
l/min
800
135
1500
135
1800
136
2200
136.5
800
171
1500
171
1800
172
2200
173
800
211
1500
211
1800
212
2200
213
800
267
1500
267
1800
269
2200
270
800
330
1500
330
1800
332
2200
333
800
399
1500
399
1800
401
2200
403
46
4
PUMP IDENTIFICATION
Each pump has an identification label, showing:
-
Pump model and version
-
Serial number
-
Max revs
-
Absorbed power HP - kW
-
Pressure bar - P.S.I.
-
Flow rate l/min - Gpm
Model, version and serial number must always be
indicated when ordering spare parts
Pressure
Gpm
bar
psi
35.7
300
4350
35.7
300
4350
35.9
300
4350
36.1
300
4350
45.2
240
3480
45.2
240
3480
45.4
240
3480
45.7
240
3480
55.7
210
3045
55.7
210
3045
56.0
210
3045
56.3
210
3045
70.6
155
2247.5
70.6
155
2247.5
71
155
2247.5
71.3
155
2247.5
87.2
125
1812.5
87.2
125
1812.5
87.6
125
1812.5
88
125
1812.5
105.4
100
1450
105.4
100
1450
106
100
1450
106.5
100
1450
Fig. 1
Power
kW
HP
73.5
100
73.5
100
73.5
100
73.5
100
73.5
100
73.5
100
73.5
100
73.5
100
84.6
115
84.6
115
85.3
116
85.3
116
73.5
100
73.5
100
73.5
100
73.5
100
73.5
100
73.5
100
73.5
100
73.5
100
73.5
100
73.5
100
73.5
100
73.5
100