Slide out Bottom
tray - Remove excess grease, then wash with warm soapy water,
then rinse.
Flavorizer ° bars and Cooking
grates
- Clean with a suitable brass bristle brush. As
needed, remove from grill and wash with warm soapy water, then rinse with water.
Catch pan - Disposable
foil trays are available,
or you can line the catch pan with
aluminum foil. To clean the catch pan, wash with warm soapy water, then rinse.
Thermometer
- Wipe with warm soapy water; clean with plastic scrub ball.
Inside cooking
module
- Brush any debris off of burner tubes. DO NOT ENLARGE
BURNER
PORTS (OPENINGS).
Wash inside of cooking box with warm soapy water
and a water rinse.
Inside Lid - While lid is warm, wipe inside with paper towel to prevent grease build-up.
Flaking built-up grease resembles
paint flakes.
Stainless
steel surfaces
- Wash with a soft cloth and a soap and water solution. Be
careful to scrub with the grain direction
of the stainless steel.
Do not use cleaners
that contain
acid, mineral
spirits
or xylene.
Rinse well after
cleaning.
Preserve
Your Stainless
Steel - Your grill or its cabinet, lid, control panel and shelves
may be made from stainless steel. To keep the stainless steel looking its best is a
simple matter. Clean it with soap and water, rinse with clear water and wipe dry. For
stubborn particles, the use o1 a non-metallic
brush can be used.
Z_ IMPORTANT:
Do not use a wire brush or abrasive
cleaners
on the stainless
steel surfaces
of your grill as this will cause
scratches.
z_ IMPORTANT:
When cleaning
surfaces
be sure to rub/wipe
in the direction
of the grain to preserve the look of your
stainless
steel.
INSTALL
GAS SUPPLY
GENERAL
SPECiFiCATiONS
FOR PiPiNG
Note: Contact
your local municipality
for building
codes regulating
outdoor
gas barbecue
installations.
In absence
of Local Codes, you must conform
to
the latest edition
of the National Fuel Gas Code: ANSI Z 223.1/NFPA
54, or CAN/
CGA-B149.1,
Natural Gas and Propane Installation
Code, WE RECOMMEND
THATTHIS
INSTALLATION
BE DONE BY A PROFESSIONAL.
Some of the following are general requirements
taken from the latest edition of the
National Fuel Gas Code: ANSI Z 223.1/NFPA
54, or CAN/CGA-B149.1,
Natural Gas and
Propane Installation
Code for complete
specifications.
,,
This barbecue is designed to operate at 4.5 inches of water column pressure (.163
psi).
,,
A manual shut-off valve must be installed outdoors,
immediately ahead of the
quick disconnect.
,,
An additional
manual shut-off valve indoors should be installed in the branch fuel
line in an accessible location near the supply line.
,,
The quick disconnect
connects to a V2 inch NPT thread from the gas source. The
quick disconnect
fitting is a hand-operated
device that automatically
shuts off the
flow of gas from the source when the barbecue
is disconnected.
,,
The quick disconnect
fitting can be installed horizontally, or pointing downward.
Installing the fitting with the open end pointing upward can result in collecting
water and debris.
,,
The dust covers (supplied
plastic plugs) help keep the open ends o1the quick
disconnect
fitting clean while disconnected.
,,
Pipe compound should be used which is resistant to the action of natural gas
when connections
are made.
,,
The outdoor connector
must be firmly attached to rigid, permanent
construction.
Z_ WARNING: Do not route the 10 foot hose under a deck.The
hose must be visible.
GAS LiNE PiPiNG
,,
If the length of the line required does not exceed 50 feet, use a 5/8" O.D. tube.
One size larger should be used for lengths greater than 50 feet.
,,
Gas piping may be copper tubing, type K or L; polyethylene
plastic tube, with a
minimum wall thickness of .062 inch; or standard weight (schedule 40) steel or
wrought iron pipe.
,,
Copper tubing must be tin-lined if the gas contains
more than 0.3 grams of
hydrogen sulfide per 100 cubic feet of gas.
,,
Plastic tubing is suitable
only for outdoor, underground
use.
,,
Gas piping in contact with earth, or any other material which may corrode the
piping, must be protected against corrosion
in an approved manner.
,,
Underground
piping must have a minimum of 18" cover.
TEST
CONNECTIONS
All connections
and joints must be thoroughly tested for leaks in accordance
with local
codes and all listed procedures
in the latest edition of the National Fuel Gas Code: ANSI
Z 223.1/NFPA
64, or CAN/CGA-B149.1
z_ DANGER
Do not use an open flame to check for gas leaks. Be sure
there are no sparks or open flames in the area while you
check for gas leaks. This will result in a fire or explosion
which can cause serious
bodily injury or death and damage
to property.
Inside wail
Outside wall
Gas supply
This is a typical
installation
of a Webere natural
gas
barbecue,
Local codes may
require different
installations,
Quick
disconnect
Use