6.2. PC Mode operation and usage
Once you have installed the MOSC FX drivers and edi:lab software, you can now start designing your own
effect setup ...
Every time you want to open the edi:lab software you have to set FIRST the MOSC FX module in "PC
Mode". As previously explained, the MOSC FX "PC Mode" is set pushing the PARAMETER control of the mixer
during 5 seconds until you see "PC" on the led display. Once the MOSC FX is in "PC MODE", connect the module
to the PC using the USB cable, and then open the edi:lab software on your PC (Desk Icon).
The internal mixer effects can be reprogrammed in real-time with the
edi:lab software. The software remotely modifies the programs of the MOSC FX
processors so that the sound result can be heard directly on the mixer, as if the
console were used normally. In "PC Mode" the EFFECT, TIME and PARAMETER
encoders of the mixer are disabled (controllable now through edi:lab software). In
«PC Mode» the MOSC FX module can be used normally including the FX CUE
function, FX INPUT level potentiometer and the DRY-WET crossfader. This allows
to open and close the edi:lab software while "live" performing with the MOSC FX
effects module.
The edi:lab control window opens the effect selected on the MOSC FX just
before going into "PC Mode" (L.F.O. Filter by default).
If the edi:lab software is closed on the PC, the MOSC FX automatically passes from "PC Mode" to normal
mode.
6.2.1. Software start up and communication check:
When you open the edi:lab software, a pop-up will always remind you to set the MOSC FX in "PC Mode".
To set the module in "PC Mode", press the TAP button (PARAMETER knob) for 5 seconds until the led display
shows "PC". Only one MOSC FX can be connected at the same time to the edi:lab.
Under "PC Mode", the digital effect selections and adjustments (TIME and PARAMETER knobs) are
disabled on the module and transferred to the computer control.
If you do not want to enter the edi:lab in "PC Mode", you can select "Demo Mode" and open the software
"stand-alone", without any communication with the module.
To exit the "PC Mode", close the edi:lab software (Edition->Exit) from the computer. In case of computer
problem, you can exit the "PC Mode" pressing the module TAP button for 5 seconds. Leaving the "PC Mode" from
the module can create some unpredictable software behaviours certain Windows Operating Systems, this is why
we recommend to exit the "PC Mode" always from the software itself, exiting the edi:lab.
It is not recommended to unplug the USB while running the edi:lab.
NOTE: Only a module can be connected at same time.