Intended Use; Product Information; Technical Data; Scope Of Delivery - salmson SUBSON Serie Instalacion Y Puesta En Servicio

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ENGLISH

4. INTENDED USE

The SUBSON series drainage and submersible waste water
pumps are used:
•for the automatic drainage of pits and shafts,
•for keeping dry yard areas and basement rooms exposed to
flooding,
•for lowering surface water,
if the waste water is not able to flow off into the sewer system
through natural fall.
The pumps are suitable for pumping slightly contaminated
water, rainwater, drainage water and washing water.
"AB" pumps versions are intended for pumping down to 2mm
suction level from the floor. This version is recommended for
mobile installation and pumping clear water.
The pumps are usually installed under water (submerged) and
can only be permanently or transportably installed vertically.
Because of the sheath current cooling, the pumps can also be
operated unsubmerged.
Submersible pumps with a mains connection cable of less than
10 metres are (according to EN 60335) only permitted for use
inside buildings, i.e. not for operating outside.
Pumps that are intended for use in or at garden ponds or similar
places must have a mains connecting cable that is not lighter
than rubber sheathed cables reference H07 RN-F (245 IEC 66)
according to EN 60335.
Danger! Mortal danger due to electric shock
The pump many not be used to drain swimming pools /
garden ponds or similar places if anyone is in the water.
WARNING! Hazardous to health!
Owing to the materials used, the pumps are not suitable
for potable water! Unpurified foul and waste water rep-
resents a health hazard.
CAUTION! Danger of property damage!
Pumping unpermitted substances can lead to product
damage.
The pumps are not suitable for water with coarse con-
tamination such as sand, fibres or combustible, caustic
fluids or for use in potentially explosive areas.
Correct use of the pump/unit also includes following these
instructions.
Any use over and beyond these is interpreted as incorrect use.

5. PRODUCT INFORMATION

5.1 Type key
Example:
SUBSON 20 MFP-A
SUBSON
Submersible pump
AB
Low suction version
20
Size
M
Single phase
F
with float switch
P
« portable » version with 10 metre cable
A
For aggressive water
(material 1.4435 (AISI316L))

5.2 Technical data

Mains voltage:
Mains frequency:
Protection class:
Insulation class:
Speed:
Max. current
consumption:
Power consumption P
Max. flow rate:
Max. delivery head:
Operating mode:
Operating mode S3
(optimum):
Recommended switch-
ing frequency:
Max. switching fre-
quency:
Free ball passage:
Nominal diameter of
the pressure port:
Admissible fluid
temperature:
briefly 3 min.:
Max. submersion depth: 3 m
Flat suction up to:
Maximum fluid density

5.3 Scope of delivery

Pump with
•3 metre connecting cable with mains plug
(model SUBSON...P : 10m )
•Connected float switch
for models SUBSON...F
•Whirl self-cleaning system (SAN function)
except for SUBSON 10 and SUBSON AB
•"Pressure port Rp 1¼
(model Subson 10 : grooved hose connector Ø25mm)
•Non-return valve
(except SUBSON 10)
•Installation and operating instructions
5.4 Accessories
Accessories must be ordered separately (see catalogue):
•Switchgear for 1 or 2 pump operation
•Alarm switchgear ALARMSON
•External monitoring devices / tripping unit
•Level control (e.g. flow switch)
•Discharge hose (5m, Ø25 or Ø35) with connector
•Accessories for transportable wet sump installation (e.g. hose
couplings, hoses, etc.).
•Accessories for stationary wet sump installation (e.g. check
valves, non-return valves, etc.)
The use of new accessories is recommended.
14
1~230 V, ± 10 %
50 Hz
IP 68
155
2900 rpm (50 Hz)
See name plate
:
See name plate
1
See name plate
See name plate
200 operating hours a year
Intermittent duty, 25 %
(2.5 min. operation, 7.5 min.
interval).
20/h
50/h
10 mm (model AB: 2 mm)
Ø 32 mm (Rp 1¼),
grooved hose connector Ø25mm
supplied with SUBSON 10
+3 to 35 °C
90°C
14 mm (model AB: 2 mm)
3
1060 kg/m

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Subson ab serieSubson 20 mfp-aSubson 10Subson 20Subson 30

Tabla de contenido