Operation
4.6.2
Concentration main alarm A2
WARNING
!
Risk of fatal injury! Leave the area immediately. A main alarm
is self-retaining and cannot be acknowledged or cancelled.
Intermittent alarm:
Alternating display of A2 and measured value.
For O
:
A1 = lack of oxygen
2
A2 = excess oxygen
After leaving the area, when the concentration has dropped below the
alarm threshold:
Press the OK key. The alarm messages are switched off.
If the measuring range is exceeded significantly at the CatEx channel
(very high concentration of flammable materials), a blocking alarm is
triggered. This CatEx blocking alarm can be manually acknowledged
by switching the instrument off and on in fresh air.
4.6.3

STEL / TWA exposure alarm

CAUTION
!
Health hazard! Leave the area immediately. After this alarm,
the deployment of personnel is subject to the relevant
national regulations.
NOTICE
i
i
The STEL alarm can be triggered with a maximum delay of
one minute.
Intermittent alarm:
28
Display A2 and
(STEL) or respectively
value alternating:
The STEL and TWA alarm cannot be acknowledged or cancelled.
Switch off the instrument. The values for the exposure evaluation
are deleted after the instrument is switched on again.
4.6.4
Battery pre-alarm
Intermittent alarm:
Flashing special symbol
Acknowledge pre-alarm: Press the OK key. Only the audible alarm
and the vibration alarm are switched off.
The battery still lasts approx. 20 minutes after the first battery
pre-alarm.
4.6.5
Battery main alarm
Intermittent alarm:
Flashing special symbol
The battery main alarm cannot be acknowledged or cancelled.
The instrument is automatically switched off again after 10 seconds.
Before the instrument is switched off, the visual, audible and
vibration alarms are activated for a short time.
4.6.6

Instrument alarm

Intermittent alarm:
Special symbol
displayed on the right side of the display:
The instrument is not ready for operation.
Contact maintenance or Draeger Service to rectify the problem.
(TWA) and measured
on the right side of the display.
on the right side of the display:
Dräger X-am 2500