Music Control - IMG STAGELINE LE-270 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
3) Tightly screw the cover for the lamp compartment
again. Never operate the unit without cover. Look-
ing directly into the lit halogen lamp may cause eye
damage due to the high brightness and the UV
radiation.
5 Mounting
The unit must safely be mounted in an expert way.
Important!
1. To prevent heat accumulation within the unit, the
mounting location must be selected in such a way
that a sufficient air circulation will be ensured
during operation. The unit must have a minimum
distance of 25 cm to adjoining surfaces and the air
vents at the housing must not be covered in any
case.
2. Pay in any case attention to a sufficient distance to
easily flammable material or material sensitive to
heat.
3. If the unit is installed as a suspended load above
persons, it must additionally be secured (e. g. by a
safety rope at the mounting bracket). Fix the
safety rope in such a way that the maximum falling
distance of the unit is 20 cm.
1) Use a support for light effect units or a stable
mounting screw to fix the unit via the mounting
bracket (2) at the desired place (e. g. at a horizontal
bar or a traverse of a lighting stand).
2) To align the unit, release the two setscrews (1) on
the mounting bracket. Adjust the desired inclination
of the unit, and retighten the screws.
6 Operation
Connect the plug of the mains cable (6) to a mains
socket (230 V~/50 Hz). Thus, the unit is switched on.
To switch off the unit, disconnect the mains plug.
For a more convenient operation it is recommend-
ed to connect the unit to a mains socket which can be
switched on and off via a light switch.
All rights reserved by MONACOR
be reproduced in any form or by any means for any commercial use.

6.1 Music control

To control the unit via the integrated microphone (5),
adjust the volume at the music system so that the
dynamic power of the music is reproduced by the
moving light beams in an optimum way. If the music
control should not operate in an optimum way,
increase the volume or reduce the distance between
speaker and light effect unit.
6.2 Focus setting
For focus setting release the setscrew (3) and adjust
the light patterns precisely by displacing the screw in
the long hole. The focus setting depends on the
distance of the unit to the projection surface.
7 Cleaning of the Optical System
The optical parts should be cleaned at regular inter-
vals, depending on impurities caused by dust, smoke,
or other particles. Only then the light can be radiated at
maximum brightness. Prior to opening the unit, dis-
connect the plug from the mains socket and let the unit
cool down for 15 minutes.
cial detergent for glass. Then carefully wipe the parts
dry.
8 Specifications
Power supply: . . . . . . . . . . . 230 V~/50 Hz
Power consumption: . . . . . . 270 VA
Lamp: . . . . . . . . . . . . . . . . . . reflector halogen lamp
Ambient temperature: . . . . . 0 – 40 °C
Dimensions: . . . . . . . . . . . . . 320 x 140 x 340 mm
Weight: . . . . . . . . . . . . . . . . . 8.7 kg
Subject to technical modifications.
®
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual may
For cleaning use a soft, clean cloth and a commer-
24 V/250 W,
type MR 16 with
base GX 5,3
GB
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

38.2070

Tabla de contenido