4. Select "Entire Data List" and confirm with E.
"
PID data are displayed.
Fig. 5:
Live data display - description from top left to
bottom right
1 PID
2 Note on scrolling
3 Value, status or note
Symbol
Function
↑
Scrolling up possible.
↓
Scrolling down possible.
↕
Scrolling up and down possible.
Read and/or erase function can be started.
Select PID with READ or ERASE and
confirm with E.
A signal or value time profile is displayed
for the PID selected.
Tab. 10: Information on scrolling and other functions
5. Select any PID for which the icon
6. Press E to display graph.
"
The graph with the selected sensor or function
is displayed.
i
E can be used to stop signal recording.
Pressing E again re-starts the measurement.
i
Section 9 provides an alphabetical list of PIDs
and what they mean.
Robert Bosch GmbH
All you need to know about OBD | OBD 150 | 39
appears.
5.10
View Freeze Data
This provides an image of the operating and am-
bient conditions at the moment in time at which
the trouble code was first generated. Freeze
frames are however not stored and displayed for
all PID numbers. A list of the PID numbers (pa-
rameter IDs) supported by the OBD 150 is given
in Section 9.
1. Switch on the ignition (position 2).
2. Connect the OBD 150 to the vehicle.
Data are read.
3. In the diagnostic menu select
"View Freeze Data" with
and confirm with E.
Trouble codes are displayed.
4. Select the trouble code and confirm with E.
"
Freeze frame data are displayed.
i
Scroll through freeze frame data using
or
.
ERASE
569630 Rev "D"
en
or
READ
ERASE
READ
|
2016-02-19