5.16

System Setup

The following settings and tests can be altered
or performed.
Menu item
Description and function
English/Metric
Setting of units
Adjust contrast
Setting of screen brightness in %
Language setup
Setting of language
Long PID Names
Option of displaying PID descriptions in the
footer can be set
Tool information
Display of OBD 150 hardware and software
information
Display Test
OBD 150 screen self-test
Keypad Test
OBD 150 button self-test
Memory Test
Integrated OBD 150 memory self-test
Program mode
Updating of OBD 150 software
Tab. 11: Functions in system setup menu
1. Switch on the ignition (position 2).
2. Connect the OBD 150 to the vehicle.
 Data are read.
3. In the diagnostic menu select "System Setup"
with
or
READ
ERASE
 The menu items are displayed.
4. Select the menu item required with
and confirm with E.
ERASE
"
Function is implemented.
5.17

Faults

Fault
Remedy
LINK ERROR
During reading
Turn the ignition key to the OFF position for 10 seconds; then return to the ON position and press
the  READ button.
Make sure the ignition key is set to ON (position 2) and not to ACCESSORIES (position 1).
During erasing
Turn the ignition key to the OFF position for 10 seconds; then return to the ON position and press
one of the following buttons with the ignition key set to ON (position 2) and not to ACCESSORIES
(position 1):
R Continue erasing operation with ERASE.
R Cancel erasing operation with READ (read again) or E (return to diagnostic menu).
A trouble code will appear again if the cause of the problem has not yet been rectified.
MIL status
If the MIL status is
problem in the circuit of the malfunction indicator light. It is then advisable to consult a workshop.
Tab. 12: Faults
|
569630 Rev "D"
2016-02-19
and confirm with E.
or
READ
ON
and the warning light does not come on with the engine running, there is a
Notes
Alteration of values with READ
Alteration of values with READ
or
Set with READ
ERASE and confirm
with E
This setting can also be made directly in the
"View data" menu.
Checking of current software version and for
Service engineer inquiries.
Instructions for updating will be provided with
the update (see Section 3.5).