LEROY-SOMER
Variable speed motors and geared motors
1.4.5 - Configuration option 4: 2 preset speeds fixed or proportional to the reference - 1 operating
direction
MAINS
SUPPLY
Terminals
Specifications
+10 V analogue source
1
rated current: 3 mA
Analogue reference input
2
Analogue input S1
3
0 V - common with terminal 6
4
Logic input S2
5
0 V - common with terminal 4
6
Logic input
7
run/stop
Logic input S3
8
Relay output 250 V - 1A
9 - 10
PARAMETER-SETTING MANUAL
VARMECA 10
GENERAL INFORMATION
L1
L2
L3
PE
9
Fault
relay
10
Switched off or faulty
On
+10V
1
External potentiometer or
2
external reference
S1
Fixed or proportional
3
preset speed selection
4
0V
S2
5
Preset speed selection
6
0V
7
Run / stop
S3
8
Stopping mode
Associated parameter setting
CDC-VMA
Terminal block configuration
P14 = 4
P15 = VP1(Hz)
P16 = VP2-1(Hz)
MINI DIP K4 = ON
Reference
0 - 10 V
4 - 20 mA
VP1-1
VP2-1
Fixed
Proportional
Reference
VP1-1
VP2-1
Stop mode
Free wheel
Ramp
Setting other parameters
see sections 2 and 3
Ref. 3264 - 4.33/b -1.00
PEGASE VMA 10
OPTION 4
VP1 OPTION 1-4(Hz)
VP2 OPTION 1-4(Hz)
Mini DIP K1
ON
OFF
S1
0
1
S2
1
0
S3
0
1