Enable Supervision Of Wireless Zones; Rf Jam Detect Zone - DSC RF5132-433 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4.3 Enable Supervision of Wireless Zones

NOTE: (for PC5010 v1.x control panels only) In order for wireless zones to be supervised, you must enable Double End
of Line (DEOL) supervision in the PC5010 control panel. For more information, refer to your Installation Manual.
NOTE: (PC5020, PC1616, PC1832, PC1864, PC501X, PC1555, PC580 v2.0 and higher only) For wireless supervision
to work, you must enable the wireless zone attribute on all wireless zones (sections [101] to [132], option [8] ON).
Wireless Supervisory Window
Each wireless device (excluding wireless keys) will send a supervisory signal periodically. If the receiver does not receive
a signal within the time programmed for the Wireless Supervisory Window, it will generate a supervisory fault.
To program the wireless supervisory window:
1. Enter [*][8][Installer Code] to enter Installer Programming.
2. Enter [804] to enter the RF5132 Module Programming.
3. Enter section [81].
4. Enter the time period for the supervisory window. The window is programmed in 15 minute increments. The default
programming is:
• 96 (x15minutes), which is equal to 24 hours for NA version, or
• 10 (x15minutes), which is equal to 2.5 hours for EU version.
Valid entries are (10) to (96), equal to 2.5 to 24 hours.
5. To exit press [#].
NOTE: Supervision must be enabled for RF Delinquency.
Disable/Enable Zone Supervision
All wireless zones have supervision enabled by default. To disable supervision for any zone, enter the following at any
system keypad:
1. Enter [*][8][Installer Code] to enter Installer Programming.
2. Enter [804] to enter the RF5132 Module Programming.
3. Enter sections [82], [83], [84] and [85]. Enable or disable supervision for each wireless zone by turning each
relevant option on or off.
4. To exit press [#].

4.4 RF Jam Detect Zone

For RF jamming detection to work, you must select an unused zone to be used as the RF Jam Detect zone. When the
receiver detects an attempt to jam the RF signal, the RF Jam Detect zone will be violated and the system will generate
a tamper signal. When the jamming signal is gone, the RF Jam Detect zone closes and the system sends a tamper
restore signal.
To enable RF jamming detection by zone:
1. Enter [*][8] [Installer's Code].
2. Enter programming section [804].
3. Select an unused zone to be the RF Jam Detect zone. Enter the 2-digit number ([01] to [32]) of the RF Jam Detect
zone on the keypad, then program the serial number as [200000].
4. Enter section [93]. Enter the 2-digit number of the RF Jam Detect zone ([01] to [32]) in the programming section.
5. Disable supervision for the RF Jam detect zone by turning the relevant option off in section [82], [83], [84] or [85].
(See section 4.3 for more information).
6. RF jamming detection is now enabled. To exit Installer programming, press [#].
10

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rf5132-868Power seriePowerseries rf5132-868

Tabla de contenido