Variations In Operating Range - Chauvin Arnoux C.A 6545 Manual De Instrucciones

Megaóhmetros
Ocultar thumbs Ver también para C.A 6545:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

7.6.1. Electromagnetic compatibility:
NF EN 61326-1 (Ed. 97) + A1, industrial environment category
7.6.2. Mechanical protection
IP 53 per NF EN 60529 (Ed. 92)
IK 04 (per NF EN 50102 Ed. 95)
7.7

Variations in operating range

Influential
quantity
of influence
Battery voltage
9 V -12 V
Temperature
-10°C...+55°C
Humidity
10%...80% HR
Frequency
15...500 Hz
AC voltage
superimposed on
0% Un...20% Un
the test voltage
(1) The terms DAR, PI, DD and the capacity and current leak measurements are included in the
quantity "M Ω "
Range
Quantity
influenced (1)
V
MΩ
V
MΩ
V
MΩ (10 kΩ to 40 GΩ)
MΩ (40 GΩ to 10 TΩ)
V
MΩ
62
Influence
typical
Max.
< 1 pt
< 1 pt
0,15% read./10°C
0,3% reading +1 pt
0,20% reading
1% reading +1 pt
0,2% reading
1% reading +2 pt
0,2% reading
1% reading +5 pt
3% L
15% L +5 pt
0,3% reading
0,5% reading +1 pt
0,1% read./% Un
0,1% read./% Un +5 pt
2 pt
3 pt

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

C.a 6547

Tabla de contenido