WIKA 232.50 Manual De Instrucciones página 16

Manómetro
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6. Commissioning, operation
Permissible ambient and operating temperatures
When mounting the pressure gauge it must be ensured that, taking into
consideration the influence of convection and heat radiation, no devia-
EN
tion above or below the permissible ambient and medium temperatures
can occur. The influence of temperature on the display accuracy must
be observed.
Permissible vibration load at the installation site
The instruments should always be installed in locations free from vibra-
tion.
If necessary, it is possible to isolate the instrument from the mount-
ing point by installing a flexible connection line between the measur-
ing point and the pressure gauge and mounting the instrument on a
suitable bracket.
If this is not possible, the following limit values must not be exceeded:
Frequency range < 150 Hz
Acceleration < 0.7 g (7 m/s
Filling level testing
The liquid filling must be checked on a regular basis.
The liquid level must not drop below 75 % of the gauge diameter.
Commissioning
During the commissioning process pressure surges must be avoided at
all costs. Open the shut-off valves slowly.
16
2
)
WIKA operating instructions pressure gauge, model 2 per ATEX

Publicidad

Tabla de contenido
loading

Tabla de contenido