CONTROLS INSTALLATION
Controls
Preferably installed in the kitchen.
Flow rate selection
Selection of ventilation flow rate is by simply pressing
on the left hand button.
• Speed 1: Nominal airflow
• Speed 2: High speed – kitchen, timed for 30 minutesIm-
proves extraction of odours and humidity due
to cooking.
• Speed 3: High speed – manual control – designed
to improve comfort throughout the house.
Only available with the high-efficiency Dee Fly system.
Bypass control (optional)
The right hand button is used to manually or automatically
control the bypass. The bypass stops pre-heating of the
fresh air when it goes through the heat exchanger.
High-efficiency Dee Fly
control with by-pass
Installation
• Control is compatible with standard electrical mountings
• Connect the wires to the electronics of the control
(see electrical connections)
• Fit the electronics section of the control and fix in place
with screws.
• Clip on the façade of the keypad.
For optimum operation, opening of the by-pass is automati-
cally managed depending on the indoor and outdoor tempe-
rature conditions. A blue light indicates automatic mode.
Filter blocked warning and system fault indicators
The red warning light on the controls shows possible mal-
functions of the Dee Fly system and tells the user that the
filter is clogged.
• Light lit constantly: Filter fault (filter blocked).
• Flashing light: Motor fault
See Maintenance and Troubleshooting)