Technical Details; Safety Instructions - aldes Dee Fly Instrucciones De Montaje

Ocultar thumbs Ver también para Dee Fly:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 92
• Renewing the air • Decreasing humidity • Eliminating bad smells • Making a contribution to hygiene and comfort.

TECHNICAL DETAILS

Average electrical consumption – Microwatt motors
Airflow (m
/h)
3
Power consumption (W-Th-C)*
Average electrical consumption – Standard motors
Airflow (m
/h)
3
Power consumption (W-Th-C)*
* Average power consumption with 1h high spead per day.
Motor casing construction
• Steel casing
• Trim in expanded polypropylene
• Microwatt motors: Two 3-speed EC motors on ball bearings
with thermal protection
• Standard motors: 2asynchronous motors 2 speeds with
thermal protection
Heat exchanger casing construction
• Expanded polypropylene casing
• Standard heat exchanger with cross flow system
• High-efficiency heat exchanger with counter flow system
• 1 extraction G4 filter
• 1 air supply F7 filter
Aeraulic connection
• Motorisation: 4 Ø160 mm connectors
• Exchanger: 4 Ø160 mm connectors

SAFETY INSTRUCTIONS

Disconnect the electrical
supply before any
operations and ensure
that the unit cannot
be started
accidentally.
Never operate
on the electrical unit
when the unit
is running
The HRV system must be capable of running 24 hours a day.
90
105
30,14
34,19
90
120
121
131
Assembly precautions
• 230V–50Hz single-phase power supply
• Connections to the electrical mains should be
fitted by a qualified professional in accordance
with the rules laid down in NF C 15-100 or in
compliance with applicable regulations in the
country of installation. A contact-breaking
device with a separation of at least 3 mm should
be used on each pole.
• The electrical connections must use flexible
cabling which must have a cross section at least
equal to that of H05VV-F or H05RR-F.
• If the supply cable is damaged it must be
replaced, by a professional, with a cable of the
same reference, respecting the rules of NF C
15-100.
120
135
150
38,87
44,96
52,45
135
150
165
135
138
140
Dimensions and Weight
• Motorisation: 570 x 570 x 270 mm – 17 kg
• Exchanger: 790 x 570 x 270 mm – 13 kg
• Exchanger with by-pass: 790 x 570 x 385 mm – 14 kg
Field of Use
The Dee Fly system is suitable for up to 8 'humid' rooms (any
room fitted with a water supply – excluding the kitchen), with a
minimum of 1 bathroom and 1 WC.
Operating temperature limits
Temperature of installation premises: 0°C/50°C. For optimum
output, the heat exchanger must be placed in a heated space.
Exhaust and fresh air temperature: -7°C/45°C
Power supply
230V – 50 Hz single-phased
Electrical protection
Microwatt motorisation: 3A (10A if offset electrical heating coil
accessory)
Standard motorisation: 10A
Precautions prior to starting up
• When starting up, all ductwork, including
exhausts and fresh air inlets, must be connected
correctly.
• Never place your hands in front of in inlet or
outlet orifice.
Installation precautions
• If installing in an open hearth fire emplacement,
refer to the applicable regulations in the country
of installation.
22
165
180
195
61,35
71,66
83,37
180
150

Publicidad

Tabla de contenido
loading

Tabla de contenido