5 Maintenance
5.3 Cleaning the exhaust filter
13
14
5.4 Spare parts and accessories
ATTENTION:
Only use original spare parts from the scope of delivery or those that you
have acquired by reordering.
Ordering address:
Page 62, „International Service"
5.5 Troubleshooting
WARNING:
Danger of injury! Never use a defective appliance! Always switch off the
appliance and disconnect it from the mains before starting troubleshoot-
ing
chapter 4.3, „Switching off".
Before contacting your authorised Royal dealer, Royal service partner or
appliance market or sending in the appliance, first follow the procedure in
the following table to check if you can solve the problem yourself.
Problem
Possible cause / solution
The appli-
The socket does not carry current.
ance will not
Test the vacuum cleaner at another socket which you are
start.
sure carries current.
Power cord is damaged. Have the power cord replaced by
Royal Appliance Customer Service, address,
„International Service".
The vacuum
The overheating protection has tripped (possibly due to
cleaner
blocked suction channels, filters, or similar).
stops sud-
Switch the appliance off and pull the plug out of the socket.
denly.
Remove the cause of overheating (e.g. by disassembling
telescopic tube and suction hose and removing the obsta-
cle and/or cleaning filters). Wait for about 45 minutes. After
the appliance has cooled off, you may switch it on again.
Cleaning in-
The dust container is full.
dicator
Empty / clean the dust container,
(Fig. 1/26)
and cleaning the dust container".
lights up.
The filter inserts are dirty.
Clean the filter inserts,
inserts".
A
A
click!
click!
click!
Page 62,
chapter 5.1, „Emptying
chapter 5.2, „Cleaning filter
B
Clean the exhaust filters each time you clean the filter inserts,
5.2, „Cleaning filter inserts".
However, clean the exhaust filter at least every six months.
1. Switch off the appliance ,
2. Push the release catches of the exhaust filter cover down (Fig. 13/A)
and fold down the exhaust filter cover.
3. Remove the exhaust filter from its holder (Fig. 13/B).
4. Hold the filter holder together with the exhaust filter in a dustbin and re-
move larger accumulations of dirt by hand.
5. Remove residual dust with a soft brush, e.g. the supplied furniture
brush (Fig. 14/A).
B
ATTENTION:
The exhaust filter cannot be washed.
6. If the exhaust filter is damaged, deformed or too soiled, replace it (or-
dering information
7. Place the clean/new exhaust filter back into its holder (Fig. 13/B).
8. Fit the exhaust filter cover on the bottom side first (Fig. 14/A) and then
hinge it upwards (Fig. 14/B).
The following accessories and spare parts can be reordered:
Item number
2288001
1 filter screen (Fig. 1/18) and
1 cyclone unit (Fig. 1/19)
2288002
2-piece filter set
(1 premotor filter [Fig. 1/10] and
1 protective motor filter [Fig. 1/17])
2288003
1 exhaust filter (Fig. 1/30)
M203
1 parquet brush (Fig. 2/4*)
M209
1 turbo brush (Fig. 2/5*)
Problem
The cleaning
The bypass vent (Fig. 1/9) is open.
results are
Close the bypass vent .
unsatisfacto-
The attached nozzle is unsuitable.
ry in spite of
Change the nozzle,
the appli-
nozzle".
ance work-
The suction power you set is unsuitable.
ing correctly.
Adjust the suction power control to suit the flooring,
chapter 4.2, „Vacuum cleaning", step 4.
The position of the "carpet/hard floor" selector (Fig. 1/5) is
unsuitable.
Set the "carpet/hard floor" selector to the correct position
for the type of floor,
step 5.
The dust container is full.
Empty / clean the dust container
and cleaning the dust container".
The filters are dirty.
Clean the respective filter or filter insert,
„Cleaning filter inserts" or
exhaust filter".
Nozzle, telescopic tube or suction hose are blocked.
Remove the obstacle. If necessary, use a long wooden
stick (e.g. a broomstick) to do this.
NOTE:
If you cannot solve the problem following these instructions, contact the
Dirt Devil customer service ( Page 62, „International Service").
chapter 4.3, „Switching off".
chapter 5.4, „Spare parts and accessories").
Description
Possible cause / solution
chapter 3.2, „Selecting the proper
chapter 4.2, „Vacuum cleaning",
chapter 5.1, „Emptying
chapter 5.3, „Cleaning the
chapter
chapter 5.2,
19