7.2.5 Technical Data AKM2G-23
U
Parameter
N
Max. Rated DC Bus Voltage
Max. Continuous Torque for ∆ T
winding = 100°C (1)(2)(4)
Max. Continuous Current for ∆ T
winding = 100°C (1)(2)(4)
Max. Continuous Torque for ∆ T
winding = 60°C (2)(4)
Max. mechanical speed (5)
Peak Torque (1)(2)(4)
Peak Current
24 V
Rated Torque (speed) (1)(2)(4)
DC
Rated Speed
Rated Power (speed) (1)(2)(4)
48 V
Rated Torque (speed) (1)(2)(4)
DC
Rated Speed
Rated Power (speed) (1)(2)(4)
72 V
Rated Torque (speed) (1)(2)(4)
DC
Rated Speed
Rated Power (speed) (1)(2)(4)
96 V
Rated Torque (speed) (1)(2)(4)
DC
Rated Speed
Rated Power (speed) (1)(2)(4)
AKM2G Instructions | 7 Technical Data
Tolerance Symbol
Electrical data
Max
V bus
Nom
Tmc
Nom
Imc
Nom
Tmc
Nom
Nmax
Nom
Tp
Nom
Ip
Trtd
Nrtd
Prtd
Trtd
Nrtd
Prtd
Trtd
Nrtd
Prtd
Trtd
Nrtd
Prtd
Kollmorgen | kdn.kollmorgen.com | August 2020
Units
AKM2G
23D
23E
V dc
480
480
Nm
1.48
1.48
ib-in
13.1
13.1
Arms
2.11
2.92
Nm
1.150 1.151 1.168
lb-in
10.2
10.2
rpm
8000 8000 8000
Nm
4.69
4.69
lb-in
41.5
41.5
Arms
8.44
11.7
Nm
1.45
1.42
lb-in
12.8
12.5
rpm
1800 2800 4100
kW
0.273 0.416 0.599
Hp
0.366 0.557 0.803
Nm
1.37
1.29
lb-in
12.1
11.4
rpm
4300 6200 8000
kW
0.615 0.839 1.02
Hp
0.825 1.12
Nm
1.23
1.19
lb-in
10.9
10.5
rpm
7600 8000
kW
0.977 0.993
Hp
1.31
1.33
Nm
1.20
1.17
lb-in
10.6
10.3
rpm
8000 8000
kW
1.00 0.978
Hp
1.35
1.31
23F
240
1.50
13.3
4.07
10.3
4.74
41.9
16.3
1.39
12.3
1.22
10.8
1.37
191