Connecting the inverter
9.2
Connecting the inverter to the battery
A
NOTICE!
Make sure that you do not reverse the polarity. Incorrect polarity can
damage the inverter.
I
NOTE
Tighten the nuts and bolts to a maximum torque of 15 Nm. Loose
connections may cause overheating.
➤ Set the main switch (fig. 5 3, page 4) to "OFF".
➤ Loosen the screw (fig. 4 1, page 4) from the red positive terminal (fig. 4 2,
page 4).
➤ Push the cable lug (fig. 4 2, page 4) of the positive cable into the red positive
terminal and fasten it with the bolt.
➤ Connect the negative cable to the black negative cable (fig. 4 4, page 4).
➤ Lay the positive cable from the inverter to the positive terminal of the vehicle
battery and connect it.
➤ Lay the negative cable from the inverter to the negative terminal of the vehicle
battery and connect it. A small spark can occur if the capacitors are being
charged in the inverter.
➤ Connect the earth terminal (fig. 5 8, page 4) to the vehicle chassis.
9.3
Connecting the 230 V power cable
➤ Connect the 230 Vw connection cable with safety plug (fig. 1 3, page 3) to the
230 Vw input jack (fig. 5 6, page 4).
➤ Connect the safety plug to the 230 Vw mains.
9.4
Connecting the 230 V output cable
!
WARNING!
Before connecting the 230 Vw output cable, make sure the inverter is
switched off at the main switch.
➤ Connect the 230 Vw connection cable with safety plug (fig. 1 2, page 3) to the
230 Vw output jack (fig. 5 7, page 4).
18
SinePower