Electrical Connections - Aprimatic ONDA 424 Instrucciones Para La Instalación

Motorreductor 24v para cancela corredera
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Electrical connections

Fig.27
BATT.1 12V 1,3Ah
BATT.2 12V 1,3Ah
Battery charger (OPTIONAL)
Battery Charger
Connector
Reversing Motor
To invert the motor polarity
reverse the position of
the 2 jumper leads.
1
2
= closing towards
right *
= closing towards
left *
* looking at the gate from inside
24 Vac
POWER SUPPLY
TRA
F1
F
N
230V 50Hz POWER GRID SUPPLY
Caution
In order to operate on the control unit, you need to remove the clear plastic cover; then
replace it at the end of interventions.
1: YELLOW - Manual function button.
2: BLUE - Manual function button, also used for machine
learning performances.
3: RED - Manual function button.
S1: Manual/Automatic selector switch.
Aprimatic Rx Connector : 3-pin connector used for
Aprimatic plug-in Radio receiver connection.
Motor Connector: 5-pin connector - Includes Motor and
Encoder.
Reversing motor: Motor polarity setting jumper
Battery Charger Connector: Plug-in connector for battery
charger (OPTIONAL).
Warning
Do not install the control
panel without having fi rst read the instructions !!!
N.B.: Pay particular attention to the polarity with
which the battery is connected to the control unit.
Warning
Any normally closed (NC) contact must be jumped
if not used.
Example:
5
6
7
8
9
ELECTRONIC CONTROL UNIT DIAGRAM
Manual / automatic switch
Manual
Reversing Motor
POWER LED
BLINK-LIGHT LED
Motor Connector
1
2
+
-
ENCODER
GND
+5Vdc
MOTOR
SIGNAL
FLASHING LIGHT
24Vdc 100mA Max
Batt.1-Batt.2: Back-up batteries 12V 1,3Ah (OPTIONAL).
TR 1: Trimmer for setting pause time before automatic
closing (see par. 7.6).
TR 2: Trimmer for setting torque threshold (see par. 7.4).
TRA: Transformer 230V -24V.
F1: Safety fuse 3,15A (delayed).
Power LED: Lights up when the power is ON.
BLINK-LIGHT LED: Lights up in the same way as the fl ashing light and
is used to check the remote control unit self-learning.
11-pin + 2-pin terminal boards:
* to reverse in case of closing toward left (see the reversing motor jumpers)
- EN 10 -
Automatic re-closing
Maximum torque threshold setting
TR1
TR2
1
2
3
YELLOW BLUE
RED
Automatic
S1
MEMORY MODULE
3
4
5
6
7
8
9
10 11 12 13
TERMINAL
FUNCTION
1 - 2
Flashing light output
3
positive power TX and RX
4
negative power TX
negative power RX
5
common for push-button and safety devices
and
6*
closing limit switch
7*
opening limit switch
8
STOP input
9
RX photocell input contact
10
START apertura pedonale
Step-by-step START
11
push-button input
12 - 13
antenna inputs
Radio module
Aprimatic RX CONNECTOR
Radioreciver Module
(OPTIONAL)
Antenna braid
ANTENNA
START (Step by step mode)
START Pedestrian opening
Photocell contact
Stop
Opening limit switch
Closing limit switch
SETTING
24 VDC
+24 VDC
GND
GND
Normally Closed
Normally Closed
Normally Closed
Normally Closed
Normally Open
Normally Open

Publicidad

Tabla de contenido
loading

Tabla de contenido