Control units for 24Vdc motors with powers under 80W.
a) The electrical installation and operating logic must comply with statutory regulations.
b) Cables of different voltages must be physically separated or otherwise adequately screened with
secondary insulation of at least 1 mm.
c) Cables must be secured by additional clamps next to their terminals.
d) Control all wiring connections are correct before powering.
e) Check the Dip-Switch settings are correct.
f) Unused N.C. inputs must be jumpered.
Terminals
Function
1-2
Power
4-5
24Vdc motor
6-7
Beacon
8-9
24 Vac
10-11
SCA
12
COM
13
STOP
14
PHOT
15
OPEN
16
CLOSE
17
PP Step-by-step
18
COM
19
PED
20
SWO
21
SWC
24-25
Antenna
26-27
EDGE
28-29
RX 2ch.
J2
Radio receiver
0-VMOT
Secondary
8
Control units CP.M24-RE / CP.M24-RI

GENERAL RULES

INPUT/OUTPUT FUNCTIONS
Description
230Vac 50Hz input (1-Neutral/2-Live)
24Vdc motor connection
24Vac max 15W beacon connection
24Vac/max 0.5A accessory power connection
IMPORTANT: If the battery charger board CB.24V is installed, the
output (without mains power connected) has a 24Vdc polarised
voltage. Make sure the devices are correctly connected.
(i.e. 8;+24Vdc - 9:-24Vdc).
24 Vac connection for gate open light – max 3W
Common for all control signal inputs.
STOP button input (N.C. contact)
Safety input, N.C. contact (e.g. photocells)
During closing: when the contact opens the motor is stopped and
the stroke direction is reversed immediately (i.e. opening).
In the opening phase: operation settable by Dip-switch 5.
OPEN button input (N.O. contact)
CLOSE button input (N.O. contact)
Step-by-step button input (N.O. contact)
Common connection for travel limit switches.
PEDESTRIAN button input (N.O. contact)
It opens for 7sec (1,5÷2m)
OPEN travel limit switch input (N.C. contact).
CLOSE travel limit switch input (N.C. contact).
Plug-in radio receiver antenna board connections
(24-signal/25-screen).
Edge contact input
Electric edge: Jumper "DAS" bridged
Mechanical edge: Jumper "DAS" open
When the sensitive edge is activated, the gate stops and its move-
ment is reversed for approx. 3s.
Edge not used: Jumper "DAS" open and jumper across terminals
26-27.
Output, second radio channel. N.O. contact, voltage free.
It is enabled with both fixed receiver and expandable two-channel
receiver
Socket for two channel radio receiver ("RE" versions)
The RI versions have a built-in radio receiver
Terminal for secondary circuit of transformer