Application Of The Burner To The Boiler - baltur BT 40 DSN 4T Instrucciones

Tabla de contenido

Publicidad

for model BT 40 ÷ 250 DSN4T (steel fixing flange)
APPLICATION OF THE BURNER TO BOILER
for model BT 300 - 350 DSN4T
REMARKS
When tightening the flange, it is important to do it evenly so that the inner faces are parallel between them.
Since the locking system is highly efficient, do not tighten the nuts too much.
During this operation (tightening of the flange locking nuts) keep the body of the burner lifted so that the
combustion head is kept in a horizontal position.
The burner is correctly fitted if the preheating tank is slightly tilted (i.e. higher on the fuel outlet side towards the
nozzle). This slight tilt prevents any build-up of gas inside the tank.
The presence of gas inside the preheating tank will considerably lengthen the time required to get the fuel up to
pressure. Therefore the burner could easily lock-out.
When fitting the burner to the boiler make sure that it is not positioned in a way that cancels out this tilt or, even
worse, that the preheater is tilted the opposite way.
APPLICATION OF THE BURNER TO BOILER
28
1 - Boiler plate
2 - Insulating gasket
3 - Burner fixing flange
4 - Elastic collar
5 - Stud bolt
6 - Locking nut with washer
7 - Nut and washer for fastening the first
flange
1 - Boiler plate
2 - Insulating gasket
3 - Burner fixing flange
4 - Stud bolt
5 - Locking nut with washer
N° 0002933330
N° 0002933340