ACO203XL
Pos : 55 /RVT/Inbetri ebnahme und Betrieb/Ver press en/02b - Gefahrenber eich AC O/ECO202, AC O202XL, AF P/EFP202, AC O/ECO203 @ 0\mod_1386247979716_18.doc x @ 1659 @ @ 1
EN
Pos : 56 /RVT/Inbetri ebnahme und Betrieb/Ver press en/04- BA beachten ACO102, ACO152, AC O/ECO202, AC O202XL, ECO301, AFP/EF P202 @ 0\mod_1386254189959_18.doc x @ 1665 @ @ 1
Pos : 57 /RVT/Inbetri ebnahme und Betrieb/Ver press en/05c - Punkt 1 + 2 ACO202XL @ 0\mod_1403009945933_18.doc x @ 2740 @ @ 1
1.
Check whether the nominal width of the press fitting matches the nominal width of the press
jaw/press collar.
2.
Comply with the system manufacturer's instructions when fitting the press jaw/press collar
(Fig. 10).
When using a press collar - Fit the adaptor jaw to the press collar as described in the press collar
manufacturer's instructions.
Pos : 58 /RVT/Inbetri ebnahme und Betrieb/Ver press en/07b - Info Pr ess bac ke AC O202XL @ 0\mod_1403010151206_18.doc x @ 2747 @ @ 1
Pos : 59 /RVT/Inbetri ebnahme und Betrieb/Ver press en/08 - Info Pr esss chling e ACO/EC O202, ACO202XL, EC O301, AF P/EFP202 @ 0\mod_1386668854154_18.doc x @ 1706 @ @ 1
Pos : 60 /RVT/Inbetri ebnahme und Betrieb/Ver press en/09a - Punkt 3 AC O102, AC O152, ACO/ECO202, ACO202XL, AF P/EF P202 @ 0\mod_1386672196372_18.doc x @ 1712 @ @ 1
3.
To start the process, press the start button.
Pos : 61 /RVT/Inbetri ebnahme und Betrieb/Ver press en/10d - Punkt 4 ACO202XL @ 0\mod_1403010916536_18.doc x @ 2768 @ @ 1
4.
When the pressing operation has been completed:
Pos : 62 /RVT/R einigung, Wartung, R eparatur /01a - Vorsic ht - Einsc halter- ACO102, ACO152, AC O202XL, ACO401, AXI/AAP102 @ 0\mod_1390815867244_18.doc x @ 1770 @ 1 @ 1
9
Cleaning, maintenance and repair
Pos : 63 /RVT/R einigung, Wartung, R eparatur /02 - Ser vic eans chrift - AC O102, AC O152, ACO/EC O202, ACO202XL, EC O301, AC O401, AFP/EF P202, AXI/AAP102 @ 0\mod_1391000010165_18.doc x @ 1790 @ @ 1
Service addresses
Novopress GmbH & Co. KG
Scharnhorststr. 1
41460 Neuss
Germany
You can find the addresses of authorised specialist workshops by contacting Novopress or at
www.novopress.de.
Pos : 64 /RVT/R einigung, Wartung, R eparatur /03a - Informati on Wartung - AC O102, ACO152, ACO/ECO202, AC O202XL @ 0\mod_1391004569271_18.doc x @ 1796 @ @ 1
Service intervals
Service and repair work may only be carried out by Novopress or the authorised Novopress specialist
workshops.
CAUTION!
Keep fingers away from the at-risk zone if no press jaw/adaptor jaw is
fitted. (Fig. 4)
Fingers risk being crushed.
Therefore:
–
Do not operate the device without the jaws.
–
Keep your fingers away from the at-risk zone.
Information!
Always comply with the operating instructions for the press tools!
Information!
Make sure that the press jaw is fully closed when the pressing operation is
complete (Fig. 11)
Information!
Ensure there is no gap between the segments of the press collar when the pressing
operation is complete.
•
if using a press collar: first detach the adaptor jaw from the press collar, then
•
detach the press jaw/press collar from the press fitting (Fig. 12).
CAUTION!
Risk of injury during cleaning or repair work from inadvertently pressing
the On switch.
Therefore:
–
Comply with the safety instructions and always remove the battery before
performing cleaning, servicing or repair work.
18