Maintenance
Flushing
Flush before changing colors, before fluid can
dry in the equipment, at the end of the day,
before storing, and before repairing equip-
ment. Use solvent that is compatible with gun
wetted parts and fluid that will be sprayed.
1. Follow Pressure Relief Procedure,
page 4.
2. Dispose of any paint in the cup.
3. Fill the cup with a small amount of solvent.
4. Spray into a grounded metal waste con-
tainer until clean solvent dispenses.
5. Follow Pressure Relief Procedure,
page 4.

Daily Cleaning

CAUTION
• Do not submerge gun in solvent. Solvent
dissolves lubricant, dries out packings, and
may clog air passages. You can immerse
front end of gun in solvent just until cup
connection is covered.
• Do not use metal tools to clean air cap
holes as this may scratch them and distort
the spray pattern.
• Use a compatible solvent.
1. Follow Pressure Relief Procedure,
page 4.
2. Clean fluid and air line filters.
3. Check for fluid leakage from gun and fluid
hoses. Tighten fittings or replace equip-
ment as needed.
312372J
4. Flush gun before changing colors and
when you are done spraying.
5. Remove cup and filter and clean them.
6. Remove air cap (1) and nozzle (2) as
instructed on page 7 and soak them in
compatible solvent.
CAUTION
Trigger gun and use gun tool (27) whenever
you tighten or remove nozzle (2) to avoid
damaging needle seat and nozzle.
7. Use a rag moistened in solvent to wipe
down outside of gun.
8. Before reinstalling air cap and nozzle, clean
them and front of gun with a soft-bristle
brush dipped into compatible solvent. Do
not use a wire brush or metal tools. To
clean out air cap holes, use a soft imple-
ment, such as a toothpick.
9. Lubricate gun.