ABB DCS 500 Manual Del Usuario página 58

Convertidor de potencia por tiristores para accionamientos de cc
Ocultar thumbs Ver también para DCS 500:
Tabla de contenido

Publicidad

SP
-14
SPEED CONTROL
2006
IN
KP
12004
OUT
DROOPING
12005
IN LIM
2008
SET1
BAL
2009
VAL1
BALREF
TORQ REF
2010
HANDLING (12403)
SET2
BAL2
TORQ REF
2011
VAL2
HANDLING (12402)
BAL2REF
2012
HOLD
HOLD
2007
CLEAR
RINT
SPC TORQMAX1
SPC TORQMIN1
(10903)
RUNNING
SET OUT TO ZERO
(11205)
BC
2014
P1
500
KP
2015
P2
0
KPSMIN
2016
P3
0
KPSPOINT
2017
P4
KPSWEAKFILT
500
2018
P5
5000
KI
2013
Torque ref
P6
0
DROOPING
2019
P7
0
TD
2020
P8
TF
50
ST5
SP
-8
TORQ REF SELECTION
2401
TREF A
2403
12401
FREE SIGNALS (12521)
LOAD SHARE
SEL1:OUT
2404
FREE SIGNALS (12519)
TREF B
2402
P1
0
TREF A FTC
2405
P2
0
TREF B SLOPE
TREF TORQMAX1
TREF TORQMIN1
(10903)
SETS SEL1:OUT TO ZERO
RUNNING
-1
ST5
Par/Corriente límite de intensidad
SP -34
EMFCONT2
EMF CONTROL
1001
P11
0
FIELD MODE
1001=1,3,5
(10907)
EMESTOP ACT
1004
FLUX REF SEL
1002
CONSTANTS (12512)
FLUX REF
(12102)
100%
SPEED ACT
100%
1012
P2
20000
FIELD WEAK POINT
1017
P13
23100
GENER.WEAK POINT
1018
cal
P14
0
FIELD WEAK DELAY
generatoric
0
1201=10
(1201)
DRIVE MODE
40
(10907)
EMESTOP ACT
TRef2
1005
&
EMF REF SEL
1003
CONSTANTS (12509)
EMF REF
1006
P1
100
LOCAL EMF REF
1016
P12
160
GENER.EMF REF
EMF ACT
(10506)
1007
EMF KP
P3
150
1008
EMF KI
P4
4905
1011
EMF REL LEV
P5
50
1009
P6
410
EMF REG LIM P
1010
P7
-4095
EMF REG LIM N
1013
P8
1187
FIELD CONST 1
1014
P9
2190
FIELD CONST 2
1015
P10
FIELD CONST 3
3255
ST10
1/8
2/8
SP
-9
TREFHND2
TORQ REF HANDLING
0
0
SEL2:TORQ/SPEED
2407
SEL2.TREF SPC
1
2408
2
SEL2.TREF EXT
SEL2:IN_LIM
Min
3
Max
4
(12001)
SP ERR
5
(11702)
ACCELCOMP
2409
FREE SIGNALS (12520)
SEL2.TORQ STEP
2406
P1
1
SEL2.TREF SEL
TORQ MAX2
TORQ MIN2
(10903)
RUNNING
-1
SET OUTPUTS TO ZERO
ST5
11001
FLUX REF 1
11002
FLUX REF SUM
11003
F CURR REF
70
90
Control de tensión de motor
3/8
SP
12403
SPEED CONTROL
(2010)
12402
401
TORQ REF
SEL2:OUT
12404
SPEED CONTROL (2011)
FLUX REF1
402
CURR REF
CONSTANTS (12526)
403
CURR STEP
CONSTANTS (12527)
404
BLOCK
405
REF TYPE SEL
P1
0
406
ARM CURR REF SLOPE
P2
1366
415
ARM CURR LIM P
416
ARM CURR LIM N
407
ARM CURR PI KP
P3
300
408
ARM CURR PI KI
P4
3200
409
ARM CONT CURR LIM
P5
2050
412
P6
ARM ALPHA LIM MAX
150
413
ARM ALPHA LIM MIN
P7
15
414
DXN
P8
0
410
ARM L
P9
0
411
P10
ARM R
0
417
ARM CURR CLAMP
P11
40
STSYN
SP
1215
P1
DCF MODE :
0
1216
DI2 (10703)
DI/OVP
1217
P2
0
OVP SELECT
SP
(10908)
FANS ON
DRIVE MODE
(1201)
1313
P1
0
F1 RED.SEL
(1001)
FIELD MODE
1301
F1 REF
1314
P2
1228
F1 SEL.REF
1302
F1 FORCE FWD
1303
F1 FORCE REV
1304
F1 ACK
1305
F1 CURR GT MIN L
P3
2047
1321
F1 CURR MIN TD
P10
200
1306
P4
F1 OVERCURR L
4710
1307
F1 CURR TC
P5
0
1308
P6
1
F1 KP
1309
F1 KI
P7
20
1311
F1 U LIM N
P8
-4096
1312
P9
4096
F1 U LIM P
ST20
SP
1310
P1
10
F1 U AC DIFF MAX
1315
P4
OPTI.REF GAIN
100
1316
P5
614
OPTI.REF MIN L
1317
P6
200
OPTI.REF MIN TD
1318
P7
80
REV.REV HYST
1319
P8
80
REV.REF HYST
1320
P9
0
REV.FLUX TD
ST20
4/8
1/8
3/8
C_CNTR_3
-75
CURRENT CONTROL
10405
ARM CURR REF
FLUX N
ARM CUR ACT
10403
CURR REF IN LIM
10404
12-PULS
CURR DER IN LIM
[1209]
1,2
10402
ARM DIR
10401
ARM ALPHA
DATA LOGGER (606)
t
DCFMOD
-105
DCF FIELDMODE
0
:
Disabled
1
:
DCF Current Control
2
:
Stand Alone
3
:
Reserved
4
:
Fexlink Node 1
5
:
Fexlink Node 2
6
:
MG Set
1
2
4
5
6
Cur.Controller for high inductive load
407
...
x8
ARM_CURR_PI_KP
... 408
ARM_CURR_PI_KI
x8
409
ARM_CONT_CUR_LIM
0
3601
REV_DELAY
15
3602
15
REV_GAP
3603
FREV_DELAY
15
2
4
5
6
Input for external Overvoltg.Protection
BC
0
A121
1
F 21
4
as FEX 1 (Receiver)
as FEX 2 (Receiver)
10916
5
RUN DCF
10917
from ext. FEXLINK
RESET DCF
11303
REF DCF
6
Fexlink as Transmitter
for FEX1 and FEX2
M1FIELD2
-30
MOTOR 1 FIELD
1201=7
P1
1001=1,3,5
CONSTANTS (12512)
100%
11301
F1 CURR REF
P2
TEST REF2
0%
P3
P4
SDCS-FEX-2
P5
or
11302
DATA LOGGER
P6
F1 CURR ACT
DCF503/504
(605)
P7
or
P8
DCF501/502
P9
-26
MOTOR 1 FIELD OPTIONS
FREE WHEELING
P1
OPTITORQUE
Control 1 y 2 corriente de campo
FIELD REVERSAL
4/8
Control corriente
de Inducio
C_MONIT
SP -104
CURRENT MONITOR
418
CURRENT
P1
32767
RISE MAX
F03
DriveLogic
Iact
0
A137
Monit.
1
F34
1
421
2
A137
method 2
P2
7
CUR RIPPLE LIM
3
F34
420
P3
CUR RIPPLE MONIT
0
419
P4
ZERO CUR DETECT
0
INTERNAL
0
CURRENT ZERO
EXTERNAL
1
SIGNAL
via Options
STSYN
M2FIELD2
SP
-28
MOTOR 2 FIELD
(10908)
FANS ON
(1201)
DRIVE MODE
1201=7
1510
0
F2 RED.SEL
1501
F2 REF
11501
1511
100%
F2 CURR REF
1228
F2 SEL.REF
TEST REF2
0%
1502
F2 CURR GT MIN L
2047
1503
4710
F2 OVERCURR L
SDCS-FEX-2
1504
F2 CURR TC
0
or
1505
11502
F2 CURR ACT
1
F2 KP
DCF503/504
1506
F2 KI
20
or
1508
F2 U LIM N
-4096
DCF501/502
1509
4096
F2 U LIM P
ST20
SP -24
MOTOR 2 FIELD OPTIONS
1507
10
F2 U AC DIFF MAX
FREE WHEELING
ST20
5/8
3ADW000066R0506_DCS500B_System description_sp_e

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dcs 500bDcf 500b

Tabla de contenido