Filter Replacement - Kemper ProfiMaster Manual De Uso

Ocultar thumbs Ver también para ProfiMaster:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 143

7.3 Filter replacement

The service life of the filter elements depends on the type and quantity of the
separated particles. To optimize the useful life of the main filter and its protection
against coarse particles, it is preceded by a pre-filter mat.
We recommend changing the pre-filter mat regularly according to the volume of work,
e.g. daily or weekly and not waiting until it is completely covered with dust.
Increasing filter clogging with dust makes the flow resistance grow and hence the unit
performance is reduced. Now it is time to replace the filter. In most cases it is
sufficient to replace the pre-filter mat. The Main filter should be replaced only after
replacing the pre-filter mat several times.
NOTE
The horn starts sounding in case of a drop blow the minimum volume flow.
Also in case of this variant, follow the instructions described in the section 7.3 Filter
replacement.
CAUTION
Cleaning of filter elements is not allowed. This would inevitably
damage the filter medium, hence the filter would loose its function
and hazardous substances would pollute the inhaled air.
During the below-described activities be particularly careful about
the main filter seal. Only undamaged seal allows high separation
efficiency level of the unit. Main filter with a damaged seal must
therefore be in any case replaced.
Product number: 150 2464
Technical changes and errors reserved.
KEMPER ProfiMaster Instruction Manual - EN
- 61 -
rev.:
2
Status as of: 05/2015

Publicidad

Tabla de contenido
loading

Tabla de contenido