6.2
Operation
6.2.1
Switching the unit on and off
The unit can be switched on and off by pressing the pneumatic
button (38/1) which is built into the cover. There is no electrical
operating unit in the pool.
6.2.2
Volume regulator
The pump's performance can be regulated with the volume
regulator (111). In this way each swimmer can set the nozzle
stream individually.
CAUTION
Injury due to massage with full nozzle stream.
Maintain a sufficient distance in order to avoid damage to
health.
NOTICE
The pump/unit may be damaged due to operation with a closed
volume regulator.
Only operate the pump/unit with an open volume regulator.
6.2.3
LED colour variations
The LED colour variations can be changed by pressing the button
38/1 repeatedly within five seconds.
Colour sequence:
•
Red
•
Green
•
Blue
•
Green – Red
•
Green – Blue
•
Red – Blue
•
Green – Red –
Blue
The colour variation will be maintained when pressed for longer
than five sceonds.
01|2018
Commissioning/Decommissioning
Change of colour:
•
one second discrete
•
30 seconds slowly dimming
•
flashing
•
seven seconds dimming
•
flickering "rolling out"
EN 45