3
Description
3.1
Components
Fig. 1
(1)
(38/1)
(54)
(111)
3.2
Function
The pump (92) is connected via the suction and pressure line with
the plastic main housing (1). The pump is switched ON/OFF with
the pneumatic button (38/1). The pool water is sucked in by the
pump (92) via the circulating annular channel in the light cover
and suction panel with a low flow rate and pumped back into the
pool under high pressure through the nozzles (54). The flow rate
of the two nozzles (54) can be controlled with the rotary knob of
the volume regulator (111). Air can optionally be added to the
nozzle stream with the air regulator (21/1). The system is
equipped for effect lighting with integrated LED submersible
lighting that can be switched ON/OFF with the pneumatic button
(38/2).
01|2018
(92)
(54)
Main housing
Pneumatic button
pump
Nozzles
Volume regulator
(1)
(111)
(21/1) (38/1)
WG23.140.034-P
(21/1)
Air regulator
(38/2)
Pneumatic button light
(92)
Pump
Description