5.6
Disassembly
Please observe the point "Decommissioning" on page 46.
1.
Remove the caps for the volume regulator (111) and air
regulator (21/1). See "Fig. 19"
2.
Loosen the tapping screws (112) and remove the light cover
(110).
3.
Bend the two offset tabs on the stainless steel cover back
towards the front and remove the stainless steel cover. See
"Fig. 17"
4.
Loosen the tapping screws (95) and remove the suction
panel (93) and hand rail (70).
5.
If necessary, loosen the tapping screws (61). Remove the
nozzle housing (102.1). When doing so, be aware of the
internal air line (4) which is fastened to the main housing (1).
6.
Loosen the screws (52). Remove the handrail (70), support
ring (28) and support ring seal (27).