ELECTRICAL SPECIFICATIONS

REFERENCE CONDITIONS

Accuracy is given in the following reference ranges:
- temperature: +23°C ± 3°C
- relative humidity: 45% to 75% RH
- battery voltage: 6 V ± 0.1 V
- position of the conductor: centred in the clamp
- DC magnetic field: the earth's field (< 40 A/m)
- external AC magnetic field: none
- external electrical field: none
- frequency of the AC component of the signal: 45 Hz to 65 Hz
The accuracy is expressed as a % of the reading (± %R) and in measurement counts
(± count).
NB: Some reference conditions are listed for specific functions, if applicable, with the elec-
trical specifications of the functions.

AC AND DC CURRENTS

Specific reference conditions
- on AC: sinusoidal signal
- on DC: AC component 0.1% of DC signal with corrected zero
A RMS
0.30 ... 59.99 A
A PEAK
0.50 ... 59.99 A
Resolution
Accuracy
2%R ±2counts +0.2A
NB: The first two ranges can be respectively forced up to 100A and 1000A on manual
RANGE mode.
Operating frequency: 10Hz to 5kHz
Response time:
- Digital display: 400 ms on normal " mode "
- Analogue display: 100 ms
Range overload:
Display of
Permitted overload: 3 kA PEAK
10 mA
3s on SMOOTH mode
" flashing " above 1500 A PEAK or DC.
60.0 ... 599.9 A
60.0 ... 599.9 A
100 mA
2%R ±2counts
5 2
600 ... 1000 A
600 ... 1500 A
1 A

Publicidad