THD and harmonic rate
DF and distortion rate
Resolution
Accuracy
NB: The accuracies given (in %) for these rates are also valid for the corresponding values
expressed in A or V.
Operating frequency
- DC to 25 times the fundamental
- fundamental between 40 Hz and 70 Hz
0.2% ... 600.0%
0.2% ... 100.0%
Rate > 10% and harmonic < 13: 5% R ± 2 counts
Rate > 10% and harmonic > 13: 10% R ± 2 counts
Rate < 10% and harmonic < 13: 10% R ± 2 counts
Rate < 10% and harmonic > 13: 15% R ± 2 counts
5 6
0.1%